Early diagnosis of cardiac implantable electronic device generator pocket infection using ¹⁸F-FDG-PET/CT
Fozia Zahir Ahmed1, Jacqueline James2, Colin Cunnington3
1Cardiovascular Institute, Faculty of Medical and Human Sciences, University of Manchester, Manchester, UK Department of Cardiology, Manchester Heart Centre, Central Manchester University Hospitals NHS Foundation Trust, Manchester, UK foziaahmed@me.com.
Aims:
To examine the utility of (18)F-fluorodeoxyglucose positron emission tomography/computed tomography ((18)F-FDG PET/CT) in the early diagnosis of cardiac implantable electronic device (CIED) generator pocket infection.
Methods And Results:
A total of 86 patients with CIEDs were evaluated with (18)F-FDG PET/CT imaging: 46 with suspected generator pocket infection and 40 without any history of infection. (18)F-FDG activity in the region of the generator pocket was expressed as a semi-quantitative ratio (SQR)-defined as the maximum count rate around the CIED divided by the mean count rate between normal right and left lung parenchyma. All patients underwent standard clinical management, independent of the PET/CT result. Patients with suspected generator pocket infection that required CIED extraction (n = 32) had significantly higher (18)F-FDG activity compared with those that did not (n = 14), and compared with controls (n = 40) [SQR: 4.80 (3.18-7.05) vs. 1.40 (0.88-1.73) vs. 1.10 (0.98-1.40), respectively; P < 0.001]. On receiver operator characteristic analysis, SQR had a high diagnostic accuracy (area under curve = 0.98) for the early identification of patients with confirmed infection (i.e. those ultimately needing extraction)-with an optimal SQR cut-off value of >2.0 (sensitivity = 97%; specificity = 98%).
Conclusion:
This study highlights the potential benefits of evaluating patients with suspected CIED generator pocket infection using (18)F-FDG PET/CT. In this study, (18)F-FDG PET/CT had a high diagnostic accuracy in the early diagnosis of CIED generator pocket infection, even where initial clinical signs were underwhelming.
More Related Videos
11:09High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET