The effect of vascular changes on the photoplethysmographic signal at different hand elevations
M Hickey1, J P Phillips, P A Kyriacou
1School of Mathematics, Computer Science and Engineering, City University London, London, EC1V 0HB, UK.
Abstract:
In order to further understand the contribution of venous and arterial effects to the photoplethysmographic (PPG) signal, recordings were made from 20 healthy volunteer subjects during an exercise in which the right hand was raised and lowered with reference to heart level. Red (R) and infrared (IR) PPG signals were obtained from the right index finger using a custom-made PPG processing system. Laser Doppler flowmetry (LDF) signals were also recorded from an adjacent fingertip. The signals were compared with simultaneous PPG signals obtained from the left index finger. On lowering the hand to 50 cm below heart level, both ac and dc PPG amplitudes from the finger decreased (e.g. 18.70 and 63.15% decrease in infrared dc and ac signals respectively). The decrease in dc amplitude most likely corresponded to increased venous volume, while the decrease in ac PPG amplitude was due to regulatory adjustments on the arterial side in response to venous distension. Conversely, ac and dc PPG amplitudes increased on raising the arm above heart level. Morphological changes in the ac PPG signal are thought to be due to vascular resistance changes, predominately venous, as the hand position is changed.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pulse