Related Experiment Video
Updated: Apr 17, 2026

Author Spotlight: A Non-Intubated Video-Assisted Thoracoscopic Surgery with Multimodal Analgesia and Sevoflurane Inhalation Anesthesia
Published on: May 26, 2023
Intubation with VivaSight or conventional left-sided double-lumen tubes: a randomized trial
Rolf Schuepbach1, Bastian Grande, Giovanni Camen
1Institute of Anesthesiology, University and University Hospital Zurich, Raemistrasse 100, 8091, Zurich, Switzerland.
Introduction:
Double-lumen endotracheal tubes (DLTs), which are commonly used for single-lung ventilation during surgery, are difficult to insert. In addition, they often move during surgical lung manipulation which can cause life-threatening complications. Flexible bronchoscopy is used routinely to establish and confirm proper DLT placement. The newly designed VivaSight DLT has an integrated camera, allowing continuous visualization of its position in the trachea. We hypothesized that the time to intubation using the VivaSight DLT would be faster than with a conventional DLT.
Methods:
We enrolled 40 adults scheduled for thoracic surgery. Patients were randomized to conventional DLT (n = 20) or VivaSight DLT (n = 20). Time to intubation was our primary outcome. Secondary outcomes were insertion success without flexible bronchoscopy, frequency of tube displacement, ease of insertion, quality of lung collapse, postoperative complaints, and airway injuries.
Results:
Time [mean (SD)] to successful intubation was significantly faster with the VivaSight DLT [63 (58) sec] compared with the conventional DLT [97 (84) sec; P = 0.03]. The VivaSight DLTs were correctly inserted during all attempts. When malpositioning of the VivaSight DLT occurred, it was easily remedied, even in the lateral position. The devices were comparable with respect to postoperative coughing, hoarseness, and sore throat. Airway injuries tended to be more common with the VivaSight DLT, although this study was underpowered for airway injuries.
Conclusion:
The VivaSight DLT camera allowed faster insertion and facilitated initial positioning. It also confirmed proper tube positioning intraoperatively and facilitated repositioning when necessary. This trial was registered at clinicaltrials.gov: NCT01807676.
Related Concept Videos
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Endoscopic Procedures III: Video Capsule Endoscopy
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....