Related Experiment Video
Updated: Apr 17, 2026

Scanning Electron Microscopic Evaluation of Surface Defects of Remover Retreatment File After Single and Multiple Uses
Published on: October 11, 2024
Accumulated hard tissue debris produced during reciprocating and rotary nickel-titanium canal preparation
Gustavo De-Deus1, Juliana Marins2, Emmanuel João Nogueira Leal Silva1
1Department of Endodontics, Grande Rio University, Duque de Caxias, Rio de Janeiro, Brazil.
Introduction:
This study compared the amount of hard tissue debris produced after different apical enlargement with single-file reciprocating systems (WaveOne [Dentsply Maillefer, Baillaigues, Switzerland] and Reciproc [VDW, Munich, Germany]) and a conventional multifile rotary system (BioRaCe [FKG Dentaire, La-Chaux-de-Fonds, Switzerland]) using micro-computed tomographic imaging.
Methods:
Thirty moderately curved mesial roots of mandibular molars presenting 2 independent root canals were selected and scanned at an isotropic resolution of 14.16 μm. The sample was assigned to 3 groups (n = 10) with respect to the root length and degree of curvature of the mesial root according to the system used for the root canal preparation: Reciproc, WaveOne, and BioRaCe. Second and third scans were taken after the root canals were prepared up to ISO sizes 25 and 40, respectively. The matched images of the mesial canals, before and after preparation, were examined from the furcation level to the apex to evaluate the amount of hard tissue debris (%). Data were statistically compared using a general linear model for repeated-measures with a significance level set at 5%.
Results:
Instrumentation systems per se did not influence the amount of hard tissue accumulation (P > .05), whereas a significant reduction in the percentage of hard tissue debris was observed after sequential enlargement in all groups (P < .05).
Conclusions:
None of the systems yielded root canals completely free from packed hard tissue debris. The increased final apical size resulted in significantly less debris accumulation for both reciprocating and rotary systems.