Purpose Of The Report:
When thyroid scintigraphy (TS) is performed after contrast-enhanced CT (CE-CT), tracer uptake of 99mTcO4 in the thyroid gland can be inhibited by free iodide. Currently, it is recommended to postpone TS until 4 to 8 weeks after CE-CT, but few data exist to support this recommendation. The purpose was to investigate the effect of CE-CT and other variables for the diagnostic quality of TS.
Patients And Methods:
This retrospective study included 196 patients subjected to TS less than 3 months after a CE-CT (median, 66 days). Patients with elevated thyroid-stimulating hormone (>4.5 mIU/L) or suspected thyroiditis were excluded. Logistic regression was used to calculate the probability of a TS of diagnostic quality with the variables days since CE-CT, age, thyroid-stimulating hormone, and kidney function (eGFR).
Results:
Days since CT and age were highly significant (P < 0.001) predictors for diagnostic TS. The probability of diagnostic quality TS after CE-CT increased with time and reached approximately 70% to 80% 6 to 8 weeks after CE-CT. Analysis of age-specific populations showed age to be a strong independent factor.
Conclusions:
Our findings are in consensus with the currently recommended interval of 6 to 8 weeks between CE-CT and TS. However, our results indicate that patient age should be taken into account, and we suggest the following delay from CE-CT to TS: 4 weeks for patients aged younger than 50 years, 6 weeks for patients aged 50 to 60 years, and 8 weeks for patients aged older than 60 years.
More Related Videos
03:55Computer-Aided Three-Dimensional Visualization in the Treatment of Locally Advanced Thyroid Cancer
Published on: June 9, 2023
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET