Related Experiment Video
Updated: Apr 17, 2026

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Lifetime comparison of Y-TZP/porcelain crowns under different loading conditions
P H Corazza1, Y Duan2, E T Kimpara3
1Department of Dental Materials and Prosthodontics, Institute of Science and Technology, Sao Paulo State University (UNESP), Eng. Francisco Jose Longo Ave., 777, Sao Jose dos Campos, SP 12245-000, Brazil; Post-Graduation Program in Dentistry, Dental School, University of Passo Fundo, BR 285, Km 171, Passo Fundo, RS 99001-970, Brazil.
Objectives:
To compare the lifetime of Y-TZP/porcelain crowns under three different load conditions using step-stress accelerated lifetime testing.
Methods:
The Y-TZP frameworks were milled using CAD/CAM, veneered with a porcelain and cemented onto dentine analogue dies. Specimens were divided according to the occlusal load condition (n=20): central fossa load (CFL), cusp tip load (CTL) and sliding contact (SC). For CFL and CTL, the cyclic load was applied parallel to the long axis of the preparation using a ceramic piston. For SC, the axial load was associated to 1mm lateral displacement at the disto-lingual cusp. Different stress profiles were used. Failures were detected with an acoustic system. A Weibull distribution (95% confidence boundary) was used to analyse the data, and fractographic principles were used to evaluate fractured specimens.
Results:
The acoustic monitor was able to detect the initial crack. The probability of failure (at 300 N load and 200,000 cycles) was statistically greater for CTL (0.63; 0.44-0.81) compared to CFL (0.23; 0.12-0.43). The Weibull modulus of CFL (2.1; 1.5-3.6) was greater than for SC (0.7; 0.5-1.2), with no difference in the lifetime. All specimens failed by chipping, which originated predominantly at the contact (66.7%) on CTL, and in the bulk of the porcelain on CFL (100%) and SC (80%).
Conclusions:
Contact at the cusp tip is more harmful than at the central fossa. Data from sliding contact are less consistent than from axial contacts, but more clinically relevant.
Clinical Significance:
The loading condition of Y-TZP/porcelain crowns can influence on the probability of failure and failure mode. The contact at the cusp tip is more harmful than at the central fossa, where the stress is better distributed. Sliding contact is a better simulator of the chewing cycle compared to axial contacts.
Related Concept Videos
Stresses under Combined Loadings
The process begins by slicing the tube at critical points and analyzing the internal forces and stress components at these sections, focusing on the centroid. Normal stresses, generated by axial forces and bending moments, are either compressive or tensile and vary across the section from...
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Normal Strain under Axial Loading
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical...
Stress: General Loading Conditions
The shearing force, possessing potential directionality within the plane of the section, is simplified into two component forces running parallel to the x and y axes....
Impact Strength of Concrete

