Related Experiment Video
Updated: Apr 17, 2026

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Dosimetric comparison of preoperative single-fraction partial breast radiotherapy techniques: 3D CRT, noncoplanar
Sua Yoo1, Rachel Blitzblau, Fang-Fang Yin
1Duke University Medical Center. sua.yoo@duke.edu.
Abstract:
The purpose of this study was to compare dosimetric parameters of treatment plans among four techniques for preoperative single-fraction partial breast radiotherapy in order to select an optimal treatment technique. The techniques evaluated were noncoplanar 3D conformal radiation therapy (3D CRT), noncoplanar intensity-modulated radiation therapy (IMRTNC), coplanar IMRT (IMRTCO), and volumetric-modulated arc therapy (VMAT). The planning CT scans of 16 patients in the prone position were used in this study, with the single-fraction prescription doses of 15 Gy for the first eight patients and 18 Gy for the remaining eight patients. Six (6) MV photon beams were designed to avoid the heart and contralateral breast. Optimization for IMRT and VMAT was performed to reduce the dose to the skin and normal breast. All plans were normalized such that 100% of the prescribed dose covered greater than 95% of the clinical target volume (CTV) consisting of gross tumor volume (GTV) plus 1.5 cm margin. Mean homogeneity index (HI) was the lowest (1.05 ± 0.02) for 3D CRT and the highest (1.11 ± 0.04) for VMAT. Mean conformity index (CI) was the lowest (1.42 ± 0.32) for IMRTNC and the highest (1.60 ± 0.32) for VMAT. Mean of the maximum point dose to skin was the lowest (73.7 ± 11.5%) for IMRTNC and the highest (86.5 ± 6.68%) for 3D CRT. IMRTCO showed very similar HI, CI, and maximum skin dose to IMRTNC (differences <1%). The estimated mean treatment delivery time, excluding the time spent for patient positioning and imaging, was 7.0 ± 1.0, 8.3 ± 1.1, 9.7 ± 1.0, and 11.0 ± 1.5min for VMAT, IMRTCO, IMRTNC and 3D CRT, respectively. In comparison of all four techniques for preoperative single-fraction partial breast radiotherapy, we can conclude that noncoplanar or coplanar IMRT were optimal in this study as IMRT plans provided homogeneous and conformal target coverage, skin sparing, and relatively short treatment delivery time.
More Related Videos
11:38Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022