Evaluation of a LC-MS method for everolimus preclinical determination in brain by using [(13)C2D4]RAD001 internal
Stefano Giovagnoli1, Tommaso Cassano2, Lorenzo Pace2
1Department of Pharmaceutical Sciences, University of Perugia, Via del Liceo 1, 06123 Perugia, Italy.
Isotopic internal standards are increasingly frequent in LC-MS analysis to control biological matrix effects in the quantitation of immunosuppressant drugs, such as everolimus (RAD001). Here we present the evaluation of a LC-MS method, exploiting [(13)C2D4]RAD001 as internal standard, for preclinical determination of RAD001 in mice brain tissue. Samples were purified by solid phase extraction. Brain and blood were collected from vehicle-treated and RAD001-treated mice. The QTOF MS detector was set to select RAD001 ammonium adducts (m/z 975.6152) and [(13)C2D4]RAD001 (m/z 981.6481). Two different UHPLC columns were preliminarily tested. The method showed linear behavior between 4 and 100ng/mL (r(2)=0.99943) and linearity was preserved in the presence of blood (r(2)=0.99107) and brain (r(2)=0.99098) matrix components. Intra-day and inter-day precision (3-19%) and accuracy (82-109%) were comparable between standards and spiked blood and brain samples. As resulting from recovery comparison (82-98%), [(13)C2D4]RAD001 compensated ion suppression phenomena maintaining method performance over a wide range of consecutive analytical runs. The comparison with a HPLC-UV method showed reliability of the method with good correlation between blood (r(2)=0.94319) and brain (r(2)=0.97773) samples and acceptable biases (<15%). This validation suggests that the investigated method could be useful for the preclinical monitoring of RAD001 brain therapeutic concentrations in animal models.
Isotopic internal standards are increasingly frequent in LC-MS analysis to control biological matrix effects in the quantitation of immunosuppressant drugs, such as everolimus (RAD001). Here we present the evaluation of a LC-MS method, exploiting [(13)C2D4]RAD001 as internal standard, for preclinical determination of RAD001 in mice brain tissue. Samples were purified by solid phase extraction. Brain and blood were collected from vehicle-treated and RAD001-treated mice. The QTOF MS detector was set to select RAD001 ammonium adducts (m/z 975.6152) and [(13)C2D4]RAD001 (m/z 981.6481). Two different UHPLC columns were preliminarily tested. The method showed linear behavior between 4 and 100ng/mL (r(2)=0.99943) and linearity was preserved in the presence of blood (r(2)=0.99107) and brain (r(2)=0.99098) matrix components. Intra-day and inter-day precision (3-19%) and accuracy (82-109%) were comparable between standards and spiked blood and brain samples. As resulting from recovery comparison (82-98%), [(13)C2D4]RAD001 compensated ion suppression phenomena maintaining method performance over a wide range of consecutive analytical runs. The comparison with a HPLC-UV method showed reliability of the method with good correlation between blood (r(2)=0.94319) and brain (r(2)=0.97773) samples and acceptable biases (<15%). This validation suggests that the investigated method could be useful for the preclinical monitoring of RAD001 brain therapeutic concentrations in animal models.
More Related Videos
08:40Absolute Quantification of Aβ1-42 in CSF Using a Mass Spectrometric Reference Measurement Procedure
Published on: March 21, 2017
09:38Dithranol as a Matrix for Matrix Assisted Laser Desorption/Ionization Imaging on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
Published on: November 26, 2013