Related Experiment Video
Updated: Apr 17, 2026

Invasive Hemodynamic Monitoring of Aortic and Pulmonary Artery Hemodynamics in a Large Animal Model of ARDS
Published on: November 26, 2018
Intrathoracic Pressure Regulation Augments Stroke Volume and Ventricular Function in Human Hemorrhage
Neil Patel1, Rich Branson, Michael Salter
1*Department of Anesthesiology, The University of Texas Medical Branch, Galveston, Texas; and †Department of Surgery, The University of Cincinnati, Cincinnati, Ohio.
Abstract:
Obtaining intravenous (i.v.) access for fluid administration is a critical step in treating hemorrhage. However, expertise, supplies, and personnel to accomplish this task can be delayed or even absent in austere environments. An alternative approach that can "buy time" and improve circulation when i.v. fluids are absent is needed. Preclinical studies show that intrathoracic pressure regulation (ITPR) can increase perfusion in hypovolemia in the absence of i.v. fluid. We compared ITPR with placebo in humans undergoing a 15% hemorrhage under general anesthesia. Paired healthy volunteers (n = 7, aged 21 - 35 years) received either ITPR or placebo on different study days. Institutional review board informed consent was obtained. Subjects were anesthetized using propofol, intubated, and mechanically ventilated and hemorrhaged (10 mL/kg). Twenty minutes after hemorrhage, ITPR (-12 cm H2O vacuum) or placebo (device but no vacuum) was administered for another 60 min. Intravenous fluid was administered when systolic blood pressure was less than 85 mmHg. Hemodynamics, cardiac function by echocardiography, and volumetric data were compared. Data were expressed in Δmean ± SEM before and after ITPR/placebo intervention. There were no differences in mean arterial pressure (ITPR, 2.1 ± 3 mmHg; placebo, -0.7 ± 3 mmHg) or fluid infused (ITPR, 17.4 ± 4 mL/kg; placebo, 18.6 ± 5 mL/kg). Urinary output and plasma volume also were not significantly different. Intrathoracic pressure regulation augmented stroke volume (ITPR, 22 ± 5 mL, placebo, 6 ± 4 mL; P < 0.05), ejection fraction (ITPR, 4% ± 1%; placebo, 0% ± 1%), and diastolic function (ΔE/e') (ITPR, -0.8 ± 0.4 vs. placebo, +0.81 ± 0.6; P < 0.05). Intrathoracic pressure regulation did not improve mean arterial pressure in healthy volunteers aged 21 to 35 years. However, ITPR augmented stroke volume, which could be caused by improved ventricular function.
Related Concept Videos
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Hormonal Regulation of Blood Pressure
Epinephrine and Norepinephrine
The adrenal medulla releases epinephrine and norepinephrine, catecholamines that enhance and extend the sympathetic or "fight or flight" physiological response. These hormones escalate heart rate and the force of contraction...
Measurement of Blood Pressure
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...