Related Experiment Video
Updated: Apr 17, 2026

Scanning Electron Microscopic Evaluation of Surface Defects of Remover Retreatment File After Single and Multiple Uses
Published on: October 11, 2024
Cleaning Effectiveness of Three NiTi Rotary Instruments: A Focus on Biomaterial Properties
Claudio Poggio1, Alberto Dagna2, Marco Chiesa3
1Department of Clinical-Surgical, Diagnostic and Pediatric Sciences, University of Pavia, Piazzale Golgi 3, 27100 Pavia, Italy. claudio.poggio@unipv.it.
Abstract:
Nickel-titanium (NiTi) instruments are commonly used for shaping the root canal system in endodontic practice. They are more flexible and have better cutting efficiency than conventional stainless steel files. The superelasticity of NiTi rotary files allows the clinicians to produce the desirable tapered root canal form with a reduced tendency to canal transportation and instrument fracture. HyFlex CM instruments are new NiTi rotary instruments with shape memory produced by an innovative methodology (patent pending) that uses a complex heating and cooling treatment that controls the material's memory. The aim of the present study was to compare the cleaning efficacy of two conventional (Mtwo, Revo-S) Ni-Ti rotary instruments with HyFlex CM. 30 single-rooted freshly extracted teeth were divided into three groups. Root canals were shaped with three NiTi instruments (Mtwo, Revo-S and HyFlex CM) using 5.25% NaOCl and 17% EDTA solutions. Specimens were fractured longitudinally and prepared for SEM analysis at standard magnification of 1000×. The presence/absence of debris smear layer and the presence/absence of smear layer at coronal, middle, and apical third of each canal were evaluated using a 5-step scale for scores. Numeric data were analyzed using Kruskall-Wallis and Mann-Whitney U statistical tests and significance was predetermined at P < 0.05. This study revealed significant differences among the various groups. Despite some minor differences, all instruments removed smear layer and debris produced during instrumentation. HyFlex CM seem to be not so effective in promoting cleanliness of root canal walls and in removing smear layer from dentine if compared to Mtwo and Revo-S.
More Related Videos
03:10Pilot In Vitro Study to Assess Cleaning Ability and Effects of Different Decontamination Methods on Implant Surfaces
Published on: November 21, 2025
06:36Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness
Published on: March 14, 2025