Calcium Carbonate Formation in the Presence of Biopolymeric Additives
Published on: May 14, 2019
Detection of calcium based neutralizers in milk and milk products by AAS
R Sowmya1, K P Indumathi1, S Arora1
1Dairy Chemistry Division, National Dairy Research Institute, Karnal, Haryana India PIN-132001.
Abstract:
Current study was carried out with the intent to standardize detection and estimation method for calcium (Ca) based neutralizers in milk and milk based indigenous products (khoa and paneer) using atomic absorption spectroscopy (AAS). Neutralized milk, khoa and paneer samples were prepared using milk with developed acidity to which calculated quantity of neutralizer (Ca based) was added. Rosalic acid test results get masked at times due to developed acidity which neutralizes the alkalinity imparted by neutralizer and hence gives false result with time in neutralizer added samples. Atomic absorption spectroscopy proved to be an accurate estimate which could detect the abnormal rise in mineral concentration even with slight addition of neutralizers in comparison with control milk and milk products. Formalin, which is a commonly used preservative in milk samples for chemical analysis, did not have any significant impact on estimation of calcium in the neutralized milk during storage.
More Related Videos
05:53A Step-By-Step Method to Detect Neutralizing Antibodies Against AAV using a Colorimetric Cell-Based Assay
Published on: December 7, 2021
07:52Detection of Antibodies That Neutralize the Cellular Uptake of Enzyme Replacement Therapies with a Cell-based Assay
Published on: September 10, 2018
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Qualitative Analysis
For instance, group IV...
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...