A zero dead-time multi-particle time and position sensitive detector based on correlation between brightness and
X Urbain1, D Bech1, J-P Van Roy1
1Institute of Condensed Matter and Nanosciences, Université Catholique de Louvain, B-1348 Louvain-la-Neuve, Belgium.
The Review of Scientific Instruments
|March 2, 2015
Summary
A novel detector system, COBRA (COrrelation between the BRightness and Amplitude), accurately links particle timing and position data. This advancement is demonstrated through experiments involving HeH dissociation, H3 fragmentation, and Xenon photo-double-ionization.
Area of Science:
- Atomic and Molecular Physics
- Particle Detection Technology
- Physical Chemistry
Background:
- Accurate multi-particle detection is crucial for understanding complex atomic and molecular processes.
- Existing methods for correlating timing and position information in particle detectors can be complex and limited.
- Developing novel, efficient detection schemes is essential for advancing experimental physics.
Purpose of the Study:
- To introduce and describe a new multi-particle time and position sensitive detector.
- To detail the COBRA (COrrelation between the BRightness and Amplitude) method for correlating timing and position data.
- To demonstrate the performance of the COBRA detection scheme through various experimental tests.
Main Methods:
- Utilized microchannel plates for timing information acquisition via fast digitization.
- Employed a phosphor screen and CMOS camera for recording particle positions.
- Implemented the COBRA method, correlating phosphor spot integrated intensity (brightness) with electrical signal amplitude.
Main Results:
- Successfully correlated timing data from microchannel plates with position data from the camera.
- Demonstrated the detector's capability in observing HeH dissociation.
- Showcased performance in analyzing H3 fragmentation and Xenon photo-double-ionization.
Conclusions:
- The COBRA detection scheme provides a robust method for multi-particle event reconstruction.
- The described detector system offers a promising new tool for atomic and molecular physics research.
- Experimental validation confirms the effectiveness of the COBRA approach in diverse physical scenarios.
Related Concept Videos
Difference from Background: Limit of Detection
10.3K
The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
The LOD indicates the presence or absence...
10.3K
Light Acquisition
9.9K
In order to produce glucose, plants need to capture sufficient light energy. Many modern plants have evolved leaves specialized for light acquisition. Leaves can be only millimeters in width or tens of meters wide, depending on the environment. Due to competition for sunlight, evolution has driven the evolution of increasingly larger leaves and taller plants, to avoid shading by their neighbors with contaminant elaboration of root architecture and mechanisms to transport water and nutrients.
9.9K
Drug Concentration Versus Time Correlation
3.0K
The plasma drug concentration-time curve is a crucial tool in pharmacokinetics, representing the drug's concentration in plasma at different time intervals post-administration. This curve illustrates the drug's journey from absorption into the systemic circulation, distribution to body tissues, and eventual elimination through excretion or biotransformation.
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the...
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the...
3.0K