Related Experiment Video
Updated: Apr 16, 2026

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Pleth variability index and fluid responsiveness of hemodynamically stable patients after cardiothoracic surgery
Brandon C Maughan1, Todd A Seigel2, Anthony M Napoli2
1When this study was done, all authors were affiliated with the Department of Emergency Medicine, Alpert Medical School of Brown University/Rhode Island Hospital, Providence, Rhode Island. Brandon C. Maughan is now a Robert Wood Johnson Clinical Scholar at the Philadelphia Veterans Affairs Medical Center and the University of Pennsylvania, and a fellow at the Leonard Davis Institute of Health Economics at the University of Pennsylvania in Philadelphia. Todd A. Seigel is now an associate physician in the Departments of Emergency Medicine and Critical Care at Kaiser Oakland Medical Center, Oakland, California. Anthony M. Napoli is an associate professor of emergency medicine at the Alpert Medical School of Brown University/Rhode Island Hospital. Brandon.Maughan@uphs.upenn.edu.
Background:
Fluid responsiveness is a measure of preload dependence and is defined as an increase in cardiac output due to volume expansion. Recent publications have suggested that variation in amplitude of the pulse oximetry waveform may be predictive of fluid responsiveness. The pleth variability index (PVI) was developed as a noninvasive bedside measurement of this variation in the pulse oximetry waveform.
Objectives:
To measure the discriminatory value of PVI for predicting fluid responsiveness as measured by pulmonary artery catheter thermodilution in patients after cardiothoracic surgery.
Methods:
A prospective observational study of hemodynamically stable postoperative cardiac surgery patients with pulmonary artery catheters. A fingertip sensor was used to measure PVI. Vital signs, PVI, and cardiac index were measured before, during, and after passive leg raise. Fluid responsiveness was defined by increase in cardiac index of greater than 15% during passive leg raise. The discriminatory value of PVI was assessed by using the Wilcoxon method to measure the area under the receiver operating curve.
Results:
In 13 months, 47 patients (24 receiving mechanical ventilation, 23 spontaneously breathing) were enrolled. Fluid responsiveness was noted in 42% of intubated patients and 48% of spontaneously breathing patients. PVI was not adequate to discriminate fluid responsiveness in intubated patients (area under curve, 0.63; P = .16) or spontaneously breathing patients (area under curve, 0.41; P = .75).
Conclusions:
Among postoperative cardiac surgery patients, PVI is not reliable for predicting fluid responsiveness as measured by pulmonary artery catheter thermodilution, regardless of ventilatory status.
More Related Videos
08:12Invasive Hemodynamic Monitoring of Aortic and Pulmonary Artery Hemodynamics in a Large Animal Model of ARDS
Published on: November 26, 2018
04:48Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
Related Concept Videos
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...