A facile approach for synthesizing molecularly imprinted graphene for ultrasensitive and selective electrochemical
Jing Luo1, Jiaojiao Cong1, Jie Liu1
1The Key Laboratory of Food Colloids and Biotechnology, Ministry of Education, School of Chemical and Material Engineering, Jiangnan University, Wuxi, Jiangsu 214122, China.
Abstract:
In this work, a novel and convenient strategy was developed to prepare molecularly imprinted polymers (MIPs) on the surface of graphene sheet. In this route, vinyl group functionalized graphene (GR/NVC) was first prepared by immobilizing 4-vinylcarbazole onto the surface of graphene via π-π interaction. The subsequent grafting copolymerization of methacrylic acid and ethylene glycol dimethacrylate in the presence of 4-nitrophenol (4-NP, template molecule) was carried out at GR/NVC surface, leading to the formation of GR/MIPs composite. The GR/MIPs composite was characterized by FTIR, fluorescence, TGA, SEM and AFM, and was used to fabricate electrochemical sensor for the detection of 4-NP. The electrochemical behavior of GR/MIPs sensor for 4-NP was investigated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The effects of the preparation conditions, such as concentration of the NVC and template, the solution pH, and incubation time, were also optimized. Under optimized conditions, the DPV current response of GR/MIPs sensor was nearly 12 times than that of the GR/NIPs sensor. It also should be noted that as compared to traditional MIP, shorter response time and much higher current response were demonstrated. In addition, the GR/MIPs sensor could recognize 4-NP from its structural analogs, indicating the excellent selectivity of the GR/MIPs sensor. The peak current is linearly proportional to the concentration of 4-NP ranging from 0.01 μM to 100 μM and 200 μM to 1000 μM with a significantly low detection limit of 5 nM, a wider response range and lower detection limits as compared to most of the previously reported electrochemical sensors for 4-NP. Furthermore, the GR/MIPs sensor exhibits good stability with adequate reproducibility and has been successfully used to determine 4-NP in water samples.
More Related Videos
11:18Manufacturing of a Nafion-coated, Reduced Graphene Oxide/Polyaniline Chemiresistive Sensor to Monitor pH in Real-time During Microbial Fermentation
Published on: January 7, 2019
09:15Iridium Oxide-reduced Graphene Oxide Nanohybrid Thin Film Modified Screen-printed Electrodes as Disposable Electrochemical Paper Microfluidic pH Sensors
Published on: November 22, 2016