Related Experiment Video
Updated: Apr 16, 2026

Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
Assessing the reliability of MRI-CBCT image registration to visualize temporomandibular joints
M A Q Al-Saleh1, J L Jaremko2, N Alsufyani1
11 School of Dentistry, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, AB, Canada.
Objectives:
To evaluate image quality of two methods of registering MRI and CBCT images of the temporomandibular joint (TMJ), particularly regarding TMJ articular disc-condyle relationship and osseous abnormality.
Methods:
MR and CBCT images for 10 patients (20 TMJs) were obtained and co-registered using two methods (non-guided and marker guided) using Mirada XD software (Mirada Medical Ltd, Oxford, UK). Three radiologists independently and blindly evaluated three types of images (MRI, CBCT and registered MRI-CBCT) at two times (T1 and T2) on two criteria: (1) quality of MRI-CBCT registrations (excellent, fair or poor) and (2) TMJ disc-condylar position and articular osseous abnormalities (osteophytes, erosions and subcortical cyst, surface flattening, sclerosis).
Results:
75% of the non-guided registered images showed excellent quality, and 95% of the marker-guided registered images showed poor quality. Significant difference was found between the non-guided and marker-guided registration (χ(2) = 108.5; p < 0.01). The interexaminer variability of the disc position in MRI [intraclass correlation coefficient (ICC) = 0.50 at T1, 0.56 at T2] was lower than that in MRI-CBCT registered images [ICC = 0.80 (0.52-0.92) at T1, 0.84 (0.62-0.93) at T2]. Erosions and subcortical cysts were noticed less frequently in the MRI-CBCT images than in CBCT images.
Conclusions:
Non-guided registration proved superior to marker-guided registration. Although MRI-CBCT fused images were slightly more limited than CBCT alone to detect osseous abnormalities, use of the fused images improved the consistency among examiners in detecting disc position in relation to the condyle.