Related Experiment Video
Updated: Apr 16, 2026

Surgical Techniques for Catheter Placement and 5/6 Nephrectomy in Murine Models of Peritoneal Dialysis
Published on: July 19, 2018
Effects of dialysis solution on the cardiovascular function in peritoneal dialysis patients
Ismail Kocyigit1, Aydin Unal, Ozkan Gungor
1Department of Nephrology, Erciyes University Medical Faculty, Turkey.
Insights
Peritoneal dialysis (PD) patients using neutral pH solutions like Physioneal showed reduced asymmetric dimethylarginine (ADMA) levels. This may lower cardiovascular event risk in PD patients.
Area of Science:
- Nephrology
- Cardiology
- Biochemistry
Background:
- Peritoneal dialysis (PD) patients face a higher cardiovascular disease burden.
- Standard PD solutions may influence cardiovascular risk factors.
Purpose of the Study:
- To compare Physioneal® and Dianeal® PD solutions.
- To assess effects on ambulatory blood pressure, echocardiographic parameters, carotid atherosclerosis, endothelial function, and serum ADMA levels.
Main Methods:
- Prospective randomized controlled study with 45 PD patients.
- Groups: Dianeal® (n=23) vs. Physioneal® (n=22).
- Measurements at baseline and 12 months: BP, ECHO, carotid IMT, FMD, ADMA.
Main Results:
- Both solutions reduced 24-hour BP, except daytime systolic BP.
- Physioneal® group showed a significant decrease in ADMA levels.
- Both groups improved flow-mediated dilation (FMD), with a trend towards greater improvement in the Physioneal® group.
Conclusions:
- Neutral pH PD solutions may decrease ADMA levels in PD patients.
- Reduced ADMA may contribute to lower cardiovascular event rates.
- Physioneal® may offer cardiovascular benefits in PD patients.
Abstract:
Objective Peritoneal dialysis (PD) patients have an increased cardiovascular burden. In this study, we aimed to compare certain PD solutions (Physioneal(®) and Dianeal(®)) in terms of the ambulatory blood pressure, echocardiographic parameters (ECHO), carotid atherosclerosis, endothelial function and serum asymmetric dimethylarginine (ADMA) level. Methods A total of 45 PD patients were enrolled in this prospective randomized controlled study: 23 patients in the Dianeal(®) group and 22 patients in the Physioneal(®) group. Ambulatory blood pressure measurements, echocardiography, carotid artery intima-media thickness measurements and flow mediated dilatation (FMD) and ADMA values were obtained at baseline and 12 months. Results The baseline parameters were similar between the groups with respect to the echocardiographic parameters, 24-hour ambulatory blood monitoring measurements and ADMA and FMD levels. All 24-hour blood pressure monitoring measurements, except for the average daytime systolic blood pressure, were significantly decreased in both groups at the first year. In the Physioneal(®) group, a significant decrease was observed with regard to the ADMA levels. Considering the FMD values, significant augmentation was seen at the end of the first year in both groups. Improvements in the FMD measurements were prominent in the Physioneal(®) group; however, this finding was not statistically significant. Conclusion The use of solutions with a neutral pH in PD patients results in decreased ADMA levels, which may be an important contributor to reductions in the incidence of cardiovascular events and deaths in this population.
Related Concept Videos
Peritoneal Dialysis I: Introduction and Procedure
Hemodialysis II: Procedure and Complications
Dialysis
Acute kidney injury develops suddenly and can be caused by pre-renal causes (e.g., hypovolemia, shock), intrinsic renal causes (e.g., acute tubular necrosis), or post-renal causes (e.g., urinary obstruction). In contrast, chronic renal failure progresses gradually over time and is often...
Dialysis
Peritoneal Dialysis III: Nursing Management
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications

