Patient load effects on response time to critical arrhythmias in cardiac telemetry: a randomized trial
Noa Segall1, Gene Hobbs, Christopher B Granger
11Department of Anesthesiology, Duke University Medical Center, Durham, NC. 2Department of Medicine and Duke Clinical Research Institute, Duke University Medical Center, Durham, NC. 3Procurement Services, Duke University, Durham, NC. 4Trauma Program, University of North Carolina Health System, Chapel Hill, NC. 5Patient Safety Research, CHE Trinity Health and Saint Alphonsus Health System, Boise, ID.
Objectives:
Remotely monitored patients may be at risk for a delayed response to critical arrhythmias if the telemetry watchers who monitor them are subject to an excessive patient load. There are no guidelines or studies regarding the appropriate number of patients that a single watcher may safely and effectively monitor. Our objective was to determine the impact of increasing the number of patients monitored on response time to simulated cardiac arrest.
Design:
Randomized trial.
Setting:
Laboratory-based experiment.
Subjects:
Forty-two remote telemetry technicians and nurses from cardiac units.
Interventions:
Number of patients monitored in a simulation of cardiac telemetry monitoring work.
Measurements And Main Results:
We carried out a study to compare response times to ventricular fibrillation across five patient loads: 16, 24, 32, 40, and 48 patients. The simulation replicated the work of telemetry watchers using a combination of real recorded patient electrocardiogram signals and a simulated patient experiencing ventricular fibrillation. Study participants were assigned to one of the five patient loads and completed a 4-hour monitoring session, during which they performed tasks-including event documentation and phone calls to report events-similar to real monitoring work. When the simulated patient sustained ventricular fibrillation, the time required to report this arrhythmia was recorded. As patient loads increased, there was a statistically significant increase in response times to the ventricular fibrillation. In addition, frequency of failure to meet a response time goal of less than 20 seconds was significantly higher in the 48-patient condition than in all other conditions. Task performance decreased as patient load increased.
Conclusions:
As participants monitored more patients in a laboratory setting, their performance with respect to recognizing critical and noncritical events declined. This study has implications for the design of remote telemetry work and other patient monitoring tasks in critical and intermediate care units.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Pathophysiology of Cardiac Performance
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Dysrhythmias VII: Nursing Management of Dysrhythmias
Chronopharmacokinetics: Circadian Rhythms and Influence on Drug Response
The time of drug administration is an important factor to consider, as it can influence the toxic dose of a drug. For example, a study conducted by Prins et al. in 1997 examined the effects of the timing of...