Clean Sampling and Analysis of River and Estuarine Waters for Trace Metal Studies
Published on: July 1, 2016
[New methodology for heavy metals measurement in water samples by PGNAA-XRF]
Abstract:
In the present paper, a new combined detection method was proposed using prompt gamma neutron activation analysis (PGNAA) and characteristic X-ray fluorescence to improve the heavy metals measurement accuracy for in-situ environmental water rejects analysis by PGNAA technology. Especially, the characteristic X-ray fluorescence (XRF) of heavy metals is induced by prompt gamma-ray directly instead of the traditional excitation sources. Thus, a combined measurement facility with an 241 AmBe neutron source, a BGO detector and a NaI-Be detector was developed to analyze the pollutants in water. The two detectors were respectively used to record prompt gamma-ray and characteristic X-ray fluorescence of heavy metals. The prompt gamma-ray intensity (I(γ)) and characteristic X-ray fluorescence intensity (I(x)) was determined by MCNP calculations for different concentration (c(i)) of chromium (Cr), cadmium (Cd), mercury (Hg) and lead (Pb), respectively. The simulation results showed that there was a good linear relationship between I(γ), I(x) and (c(i)), respectively. The empirical formula of combined detection method was given based on the above calculations. It was found that the combined detection method was more sensitive for high atomic number heavy metals like Hg and Pb measurement than low atomic number like Cr and Cd by comparing and analyzing I(γ) and I(x). The limits of detection for Hg and Pb by the combined measurement instrument were 17.4 and 24.2 mg x kg(-1), respectively.
More Related Videos
05:35Quantification of Metal Leaching in Immobilized Metal Affinity Chromatography
Published on: January 17, 2020
09:51TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples
Published on: September 19, 2025
Related Concept Videos
Gravimetry: Overview
In precipitation gravimetry, the analyte is converted into a precipitate and weighed. For example, the silver content in a sample can be estimated by precipitating and...
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Atomic Emission Spectroscopy: Overview