Related Experiment Video
Updated: Apr 16, 2026

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Computer-assisted interpretation of planar whole-body bone scintigraphy in patients with newly diagnosed prostate
Lars J Petersen1, Jesper C Mortensen, Henrik Bertelsen
1aDepartment of Nuclear Medicine, Clinical Cancer Research Center, Aalborg University Hospital bDepartment of Clinical Medicine, Aalborg University, Aalborg cDepartment of Nuclear Medicine, Regional Hospital West Jutland, Herning dDepartment of Clinical Physiology and Nuclear Medicine, Randers Hospital, Randers eDepartment of Clinical Physiology, Viborg Hospital, Viborg, Denmark.
Purpose:
The aim of this study was to compare the diagnostic properties of EXINI Bone(BSI) in newly diagnosed prostate cancer in comparison with expert reading.
Materials And Methods:
Bone scintigraphy was performed in consecutive patients referred for staging at three clinics (342 patients with DICOM file format, 272 with Interfile format). Images were reported by three independent readers on a four-point scale (class 1-4) and by using a dichotomous outcome (M1 or M0). The software analyzed data in balanced mode, as well as using 'patient-specific' settings (based on tumor characteristics), and classified outcome as normal (N), probably normal (pN), probably abnormal (pA), and abnormal (A).
Results:
Classification of bone metastasis using the software (pA+A) versus experts (class 3+4) showed a sensitivity of 93.3%, specificity of 89.3%, positive predictive value of 57.5%, and negative predictive value of 98.9% with DICOM files. The diagnostic properties of the software were notably different with Interfile format. For example, expert M1 versus software A showed a sensitivity of 90.0%, specificity of 98.9%, positive predictive value of 88.2%, and negative predictive value of 98.3% with DICOM files, versus 69.2, 88.2, 38.3, and 96.4% with Interfile format, respectively. Generally, patient-specific settings did not influence the diagnostic characteristics of the software versus balanced setting with expert reading as reference.
Conclusion:
EXINI Bone(BSI) showed high sensitivity and specificity for bone metastasis in patients with newly diagnosed prostate cancer. The software ruled out metastasis with confidence, whereas the positive predictive value was modest. The diagnostic properties were different for DICOM and Interfile file formats.
Related Concept Videos
Imaging Studies III: Computed Tomography
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET