Quiet Submillimeter MR Imaging of the Lung Is Feasible with a PETRA Sequence at 1.5 T
Gaël Dournes1, David Grodzki1, Julie Macey1
1From the Center for Cardiothoracic Research of Bordeaux, University of Bordeaux, Bordeaux, France (G.D., P.O.G., M.F., M.M., P.B., F.L.); Inserm, Center for Cardiothoracic Research of Bordeaux, U1045, F-3300, 146 rue Léo Saignat, 33076 Bordeaux, France (G.D., P.O.G., M.F., M.M., P.B., F.L.); Department of Thoracic and Cardiovascular Imaging, Department of Respiratory Disease, Department of Functional and Respiratory Examination, Centre Hospitalier Universitaire (CHU) de Bordeaux, Pessac, France (G.D., J.M., P.O.G., M.M., P.B., F.L.); Department for Imaging of the Woman and Child, Pediatric Pneumology Unit, CHU de Bordeaux, Bordeaux, France (M.F., J.F.C.); CHU de Bordeaux, CIC 0005, Bordeaux, France (M.F.); and Department of Magnetic Resonance, Siemens Healthcare, Erlangen, Germany (D.G.).
Purpose:
To assess lung magnetic resonance (MR) imaging with a respiratory-gated pointwise encoding time reduction with radial acquisition (PETRA) sequence at 1.5 T and compare it with imaging with a standard volumetric interpolated breath-hold examination (VIBE) sequence, with extra focus on the visibility of bronchi and the signal intensity of lung parenchyma.
Materials And Methods:
The study was approved by the local ethics committee, and all subjects gave written informed consent. Twelve healthy volunteers were imaged with PETRA and VIBE sequences. Image quality was evaluated by using visual scoring, numbering of visible bronchi, and quantitative measurement of the apparent contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR). For preliminary clinical assessment, three young patients with cystic fibrosis underwent both MR imaging and computed tomography (CT). Comparisons were made by using the Wilcoxon signed-rank test for means and the McNemar test for ratios. Agreement between CT and MR imaging disease scores was assessed by using the κ test.
Results:
PETRA imaging was performed with a voxel size of 0.86 mm(3). Overall image quality was good, with little motion artifact. Bronchi were visible consistently up to the fourth generation and in some cases up to the sixth generation. Mean CNR and SNR with PETRA were 32.4% ± 7.6 (standard deviation) and 322.2% ± 37.9, respectively, higher than those with VIBE (P < .001). Good agreement was found between CT and PETRA cystic fibrosis scores (κ = 1.0).
Conclusion:
PETRA enables silent, free-breathing, isotropic, and submillimeter imaging of the bronchi and lung parenchyma with high CNR and SNR and may be an alternative to CT for patients with cystic fibrosis.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...