Between-Scanner and Between-Visit Variation in Normal White Matter Apparent Diffusion Coefficient Values in the
1TeraRecon Inc., 4000 E 3rd Ave., Suite 200, 94404, Foster City, CA, USA. jinghuo@gmail.com.
Clinical Neuroradiology
|March 21, 2015
Summary
Scanner variations impact brain apparent diffusion coefficient (ADC) measurements in glioblastoma trials. While baseline ADC is consistent, variability in ADC coefficient of variation (CV) exists between scanners, affecting reproducibility.
Area of Science:
- Radiology
- Neuro-oncology
- Medical Imaging
Background:
- Glioblastoma multiforme (GBM) requires consistent imaging for clinical trials.
- Apparent diffusion coefficient (ADC) measurements are sensitive to imaging parameters.
- Multi-center trials necessitate understanding between-scanner and between-visit variability.
Purpose of the Study:
- To assess between-scanner variation in brain ADC measurements.
- To evaluate between-visit reproducibility of ADC in a multi-center GBM trial.
- To identify factors influencing ADC measurement consistency across different scanners and visits.
Main Methods:
- Calculated ADC maps from diffusion-weighted images from 52 patients across six sites.
- Utilized seven scanner models from two vendors with varying magnetic field strengths.
- Analyzed median ADC and coefficient of variation (CV) in normal white matter regions of interest.
Main Results:
- No significant difference in baseline median ADC across scanner models, vendors, or magnetic fields.
- Significant differences in baseline ADC CV were observed between scanner models (p=0.0002).
- No between-scanner differences in ADC changes between visits, but significant differences in ADC values between successive visits for the whole group.
Conclusions:
- Scanner variability, likely due to image noise, significantly impacts ADC coefficient of variation.
- Consistent scanner parameter setup is crucial for improving the reproducibility of ADC measurements between visits.
- Standardized imaging protocols are recommended for multi-center glioblastoma trials using ADC measurements.