Related Experiment Video
Updated: Apr 16, 2026

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Polymer-coated sample cup for quantitative analysis of semi-volatile phthalates in polymeric materials by thermal
Akihiko Hosaka1, Atsushi Watanabe1, Chuichi Watanabe1
1Frontier Laboratories Ltd., 1-8-14, Saikon, Koriyama, Fukushima 963-8862, Japan.
Abstract:
A new "polymer-coated" sample cup useful for the analysis of phthalates in polymeric materials by thermal desorption (TD)-GC/MS using a temperature programmable furnace type pyrolyzer as a TD device was developed to suppress the emission of semi-volatile phthalates such as dimethyl phthalate (DMP) and diethyl phthalate (DEP) during the measurements. The inner surface of a sample cup was coated by polymers which act as a sorbent for the phthalates. Three polymers, polyvinyl chloride, polystyrene and poly (methyl methacrylate), were chosen as the coating polymers. A mixture of ten phthalates including DMP and DEP was used as the test sample to estimate the performance of the sample cups. When a conventional sample cup without any polymer coating was used, 90 and 50% reductions in the peak areas of DMP and DEP were respectively observed at the waiting time of 200 min. On the contrary, no reduction of peak area of DMP and DEP during the same waiting time was observed with any one of the three coating polymers at the proper polymer film thickness. These results suggest that the polymer-coated sample cup suppresses the emission of semi-volatile phthalates and is effective for the analysis of phthalates containing DMP and DEP by TD-GC/MS.
More Related Videos
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...

