A new method using matrix solid-phase dispersion (MSPD) and gas chromatography-tandem mass spectrometry (GC-MS/MS) efficiently quantifies 40 organic contaminants in molluscs. This validated technique detects priority and emerging pollutants at low levels in seafood.
Area of Science:
- Environmental Chemistry
- Analytical Chemistry
- Food Safety
Background:
- Molluscs are susceptible to accumulating organic contaminants from aquatic environments.
- Accurate quantification of diverse pollutants is crucial for risk assessment and regulatory compliance.
- Existing methods for contaminant analysis in complex matrices like molluscs can be labor-intensive and require extensive sample preparation.
Purpose of the Study:
- To optimize and validate a matrix solid-phase dispersion (MSPD) method coupled with gas chromatography-mass spectrometry (GC-MS and GC-MS/MS).
- To develop a sensitive and reliable analytical procedure for quantifying up to 40 priority and emerging organic contaminants in molluscs.
- To apply the validated method for the analysis of environmental samples from Colombia and Nicaragua.
Main Methods:
- Optimization of the MSPD procedure, focusing on the clean-up strategy using specific solid supports and elution solvents.
- Validation of the method using gas chromatography-tandem mass spectrometry (GC-MS/MS), assessing linearity, repeatability, reproducibility, and limits of detection.
- Accuracy evaluation through spiked samples, laboratory reference material, and standard reference material (SRM 2977).
Main Results:
- The optimized MSPD method achieved good recoveries and was validated for 40 analytes, including PAHs, PCBs, PBDEs, OCPs, OPPs, and musk fragrances.
- GC-MS/MS analysis demonstrated excellent linearity (r(2) > 0.980), acceptable repeatability (RSD < 17%), and low detection limits (0.010–2.74 ng mL⁻¹).
- The method was successfully applied to mollusc samples from Colombia and Nicaragua, detecting various contaminants at low ng g⁻¹ levels.
Conclusions:
- The developed MSPD-GC-MS/MS method offers an efficient and accurate approach for the simultaneous determination of a wide range of organic contaminants in molluscs.
- This validated technique provides a valuable tool for monitoring environmental pollution and ensuring the safety of seafood.
- The application of the method confirmed the presence of target contaminants in molluscs from the studied regions, highlighting the need for continued environmental surveillance.