Range of motion determined by multidetector-row computed tomography in patients with cervical ossification of the
Keigo Ito1, Yasutsugu Yukawa1, Masaaki Machino1
1Department of Orthopedic Surgery, Chubu Rosai Hospital, Nagoya, Japan.
Abstract:
The purpose of this study was to measure range of motion (ROM) in patients with cervical ossification of posterior longitudinal ligament (C-OPLL) by multidetector-row computed tomography (MDCT), and to investigate the influence of dynamic factors. The study included 101 patients with C-OPLL and 99 normal control patients. Preoperative MDCT were taken in all subjects in maximum neck flexion and extension. ROM at each disc level between C2/3 and C7/T1 in sagittal view was measured. Ossification morphology at each disc segment was divided into 6 groups: covered disc, covered vertebra, unconnected vertebra, connected vertebra (continuous), connected vertebra (localized), and others. The relationship between ROM and the group of ossification morphology was also investigated. ROM of adjacent intervertebral disc in connected vertebrae (continuous and localized) and those of others were investigated for each group. The average ROM of covered disc group was significantly higher than that of connected vertebra (continuous, localized). The average ROM of connected vertebra (continuous) group was significantly lower than that of covered disc group, others group, and normal control. There was no significant difference between ROM of adjacent intervertebral disc in connected vertebrae and others, but the average ROM of the connected vertebra group was significantly lower than that of the covered disc group and normal control group. Dynamic factor was reduced at continuous segment, but it was not increased in adjacent intervertebral disc.
More Related Videos
07:12Laminectomy for the Removal of Thoracic Ossification of the Ligamentum Flavum TOLF Using Ultrasonic and Conventional Osteotomes
Published on: April 21, 2023
12:25C-arm-Free Simultaneous OLIF51 and Percutaneous Pedicle Screw Fixation in a Single Lateral Position
Published on: September 16, 2022
Related Concept Videos
Imaging Studies III: Computed Tomography
Articulations of the Vertebral Column
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Eccentric Axial Loading in a Plane of Symmetry