Externally activated antitachycardia pacemaker with noninvasive electrophysiologic re-testing capability.

K Aonuma, J J Rozanski, S S Barold

    Pacing and Clinical Electrophysiology : PACE
    |March 1, 1985
    PubMed
    Summary

    A special pacemaker effectively treated drug-resistant supraventricular tachycardia in three patients. However, success rates varied for ventricular tachycardia, indicating a need for further development in pacemaker technology for arrhythmia management.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    The glucagon-like peptide-1 receptor agonist liraglutide improves hypoxia-induced pulmonary hypertension in mice partly via normalization of reduced ET(B) receptor expression.

    Physiological research·2018
    Same author

    True vs. pseudo-electrical ventricular alternans sustained by ventricular premature complexes.

    Herzschrittmachertherapie & Elektrophysiologie·2018
    Same author

    A review of the atrial upper rate algorithms of St. Jude Medical (Abbott) cardiac implantable electronic devices : Incidence of repetitive nonreentrant ventriculoatrial synchrony (RNRVAS).

    Herzschrittmachertherapie & Elektrophysiologie·2017
    Same author

    Erratum to: Noise from a dysfunctional atrial lead detected as atrial fibrillation by a cardiac implantable electronic device.

    Herzschrittmachertherapie & Elektrophysiologie·2017
    Same author

    Diagnosis of myocardial infarction and ischemia in the setting of bundle branch block and cardiac pacing.

    Herzschrittmachertherapie & Elektrophysiologie·2016
    Same author

    Unusual cause of desynchronization in a cardiac resynchronization device.

    Herzschrittmachertherapie & Elektrophysiologie·2012

    Area of Science:

    • Cardiology
    • Biomedical Engineering

    Background:

    • Drug-resistant supraventricular tachycardia (SVT) and ventricular tachycardia (VT) pose significant clinical challenges.
    • Pacemaker technology offers potential therapeutic options for managing these arrhythmias.

    Observation:

    • An Omni Orthocor 234A pacemaker was implanted in nine patients (3 with SVT, 6 with VT).
    • The device uses an external unit for stimulation at various intervals (195-500 ms).
    • Noninvasive electrophysiology studies were conducted using a triggered mode responsive to chest wall stimulation.

    Findings:

    • Effective treatment was observed in three patients with reciprocating SVT over a 2.2-year follow-up.
    • Four out of six patients with VT remained successfully managed during a 1.9-year follow-up.
    • The device demonstrated utility in serial noninvasive electrophysiologic testing.

    Related Experiment Videos

    Implications:

    • This pacemaker technology shows promise for selected patients with specific tachyarrhythmias.
    • Further refinement is needed for broader clinical application in arrhythmia management.
    • The device may aid in long-term clinical follow-up and electrophysiologic testing.