Related Experiment Video
Updated: Apr 15, 2026

Structured Approach to Colonoscopy Technique Optimization: A Single-Center Experience with Novice Endoscopists
Published on: July 11, 2025
Adenoma detection rate varies greatly during colonoscopy training
Sascha C van Doorn1, Robert B Klanderman1, Yark Hazewinkel1
1Department of Gastroenterology and Hepatology, Academic Medical Centre, University of Amsterdam, Amsterdam, the Netherlands.
Background:
The adenoma detection rate (ADR) is considered the most important quality indicator for colonoscopy and varies widely among colonoscopists. It is unknown whether the ADR of gastroenterology consultants can already be predicted during their colonoscopy training.
Objective:
To evaluate the ADR of fellows in gastroenterology and evaluate whether this predicts their ADR as gastroenterology consultants.
Design:
Retrospective observational study.
Setting:
Academic and regional centers.
Patients:
Symptomatic patients undergoing colonoscopy.
Main Outcome Measurements:
The variance in ADR among 7 gastroenterology fellows during their training (between May 2004 and March 2012) and of the same fellows after they registered as consultants (between October 2011 and April 2014) was evaluated. Multivariate logistic regression was performed to compare the highest detector (endoscopist with highest ADR) with the individual fellows and to evaluate whether an ADR of 20% or higher during the training was predictive of a high ADR as a consultant.
Results:
During training, ADRs ranged from 14% to 36% (P < .001). Compared with the highest detector, the OR for detecting an adenoma ranged from 0.64 (95% CI, 0.40-1.03) to 0.29 (95% CI, 0.17-0.48). After registration, ADR ranged from 19.8% to 40.2% (P = .066). Compared with the highest detector during consultancy, the OR ranged from 0.64 (95% CI, 0.34-1.21) to 0.26 (95% CI, 0.13-0.52). Only 2 fellows significantly improved their ADR after completing their training. An ADR lower than 20% during training was associated with a lower ADR as a consultant (OR 0.51; 95% CI, 0.30-0.87).
Limitations:
Retrospective study.
Conclusions:
Variance in ADR is already present during the endoscopy training of gastroenterology fellows. Most fellows do not improve their ADR after completing their training. These findings suggest that the ADR can be predicted during colonoscopy training, and we suggest that feedback and benchmarking should be implemented early during training of fellows in an effort to improve ADR in future daily practice as a consultant.
More Related Videos
Related Concept Videos
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Assessment of the Rectum and Anus
Rectal Inspection
Begin by inspecting the perianal and anal areas for color, texture, rashes,...
Endoscopic Procedures III: Video Capsule Endoscopy
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to: