Related Experiment Video
Updated: Apr 15, 2026

Automated Modular High Throughput Exopolysaccharide Screening Platform Coupled with Highly Sensitive Carbohydrate Fingerprint Analysis
Published on: April 11, 2016
Analysis of underivatized cellodextrin oligosaccharides by capillary electrophoresis with direct photochemically
Elodie Alinat1,2,3, Selma Jemmali1,3, Nathalie Delaunay1,3
1PSL Research University, ESPCI ParisTech, Laboratory of Analytical and Bioanalytical Sciences, and Miniaturization (LSABM), Paris, France.
Abstract:
This work focuses on the development of a CE method allowing, for the first time, the simultaneous separation of the underivatized first seven cellodextrin oligomers (glucose, cellobiose, cellotriose, cellotetraose, cellopentaose, cellohexaose, and celloheptaose), with a view to analyze the hydrolysates obtained after partial acid depolymerization of nitrocellulose, and eight carbohydrates (ribose, xylose, fructose, mannose, galactose, maltose, lactose, and sucrose), which might be potential interfering compounds in explosives samples. Separation was achieved with a highly alkaline BGE containing sodium chloride and direct mid-UV-absorbance detection was performed after photo-oxidation in the detection window. EOF was reversed to speed up the analysis using a dynamic capillary coating by hexadimethrine bromide. A central composite design was carried out to determine the effects of BGE conductivity and sodium hydroxide concentration on resolutions between neighboring peaks, and analysis time. A desirability analysis on modeled responses was applied to maximize resolutions and to minimize analysis time. The simultaneous analysis in 20 min total runtime of the 15 carbohydrates plus internal reference (naphthalene sulfonate) was carried out at 25°C with a BGE composed of 77.4 mM NaOH and 183 mM NaCl to adjust the conductivity at the optimum value. Finally, the resolution robustness was checked. This new method should also be of interest to monitor food and nonfood crop products.
Related Concept Videos
Electrophoresis: Overview
There...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Capillary Electrophoresis: Instrumentation
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact...

