Related Experiment Video
Updated: Apr 15, 2026

Ensemble Force Spectroscopy by Shear Forces
Published on: July 26, 2022
Apparent shear sensitivity of molecular rotors in various solvents
Adnan Mustafic1, Kristyna M Elbel, Emannuel A Theodorakis
1College of Engineering, University of Georgia, 597 D. W. Brooks Drive, Athens, GA, 30602, USA.
Abstract:
Fluorescent environment-sensitive dyes often change their spectral properties concomitantly with multiple solvent properties, such as polarity, protonation, hydrogen bond formation, or viscosity. Careful consideration of the response is needed when a fluorescent dye is used to report a single property. Recently, we observed an increase of emission intensity of viscosity-sensitive molecular rotors in fluids subject to flow and speculated that either polar-polar interaction or hydrogen bond formation play a role in the apparent flow sensitivity. In this study, we show experimental evidence that photoisomerization to an isomer with a lower quantum yield, first proposed by Rumble et al. (J Phys Chem A 116(44):10786-10792, 2012), plays a key role in the observed phenomenon. We subjected four molecular rotors with different electron acceptor motifs to fluid flow in solvents of different polarity and ability to form hydrogen bonds. We also measured the isomerization dynamics in a custom fluorophotometer with extremely low light exposure. Our results indicate that the photoisomerization rate depends both on the solvent and on the electron acceptor group, as does the recovery of the original isomer in the dark. In most solvents, recovery of the dark isomer is much more rapid than originally reported, and a state of quasi-equilibrium between both isomers is possible. Moreover, the sensitivity (i.e., relative intensity increase at the same flow rate) is also solvent-dependent. The intensity increase can be detected at very low velocities (as low as 0.06 mm/s). Characteristic for fluorescent dyes is the high spatial resolution, and no flow measurement device with comparable sensitivity and spatial resolution exists, although the nature of the solvent needs to be taken into account for quantitative flow measurement.
Related Concept Videos
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
¹H NMR of Conformationally Flexible Molecules: Temporal Resolution
Properties of Enantiomers and Optical Activity
Solvents
A...
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
According to Hooke's law, the vibrational frequency is directly proportional to...
¹H NMR of Conformationally Flexible Molecules: Variable-Temperature NMR