Increased physiologic intensity during walking and running on a non-motorized, curved treadmill
James M Smoliga1, Eric J Hegedus1, Kevin R Ford1
1Human Biomechanics and Physiology Laboratory, Department of Physical Therapy, High Point University, High Point, NC 27268, USA.
Objective:
To determine whether exercise performed on a non-motorized, curved treadmill (NMCT) provides greater physiologic stimulus compared to a standard motorized treadmill (SMT).
Study Design:
Crossover.
Setting:
Clinical research laboratory.
Participants:
10 healthy athletic adults.
Main Outcome Measures:
Participants walked (1.34 m s(-1)) for 3 min and ran (2.24 m s(-1)) for 4 min on NMCT and SMT (randomized order) while metabolic data and rating of perceived exertion (RPE) were collected. Participants then identified preferred easy and moderate intensity training paces on each treadmill while blinded to speed. Repeated-measures ANOVA and Wilcoxon Signed-Rank tests were used to compare responses between treadmills.
Results:
Intensity was significantly greater (P < 0.001) for NMCT than SMT [mean (95% confidence interval): Walking = 5.9(5.3,6.4) vs. 3.4(3.0,3.7) METs; Running = 10.7(9,6,11.7) vs. 7.3(6.8,7.8) METs]. Overall RPE was significantly greater (P < 0.01) on NMCT than SMT for walking [median (inter-quartile range): 7(1) vs. 6(0.8)] and running [11.5(3) vs. 8(2.5)]. Preferred speed was significantly slower on NMCT than SMT for easy [2.5(2.3,2.7) vs. 2.8(2.5,3.1) m s(-1)] and moderate [3.2(3.0,3.4) vs. 3.5(3.1,3.9) m s(-1)] intensities.
Conclusions:
NMCT elicits greater physiological stimulus than SMT with small, though statistically significant, changes in RPE at matched speeds. Clinicians must be aware of differences in intensity and RPE when prescribing exercise on NMCT.
More Related Videos
09:19Short Session High Intensity Interval Training and Treadmill Assessment in Aged Mice
Published on: February 2, 2019
11:25Simultaneous Scalp Electroencephalography EEG, Electromyography EMG, and Whole-body Segmental Inertial Recording for Multi-modal Neural Decoding
Published on: July 26, 2013
Related Concept Videos
Exercise and Cardiovascular Response
Light to moderate physical activity initiates a series of interconnected responses in the body. The heart rate modestly increases in anticipation of the workout, followed by widespread vasodilation as oxygen consumption by skeletal muscles increases. This results in decreased peripheral resistance, increased capillary blood flow, and accelerated...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes