Related Experiment Video
Updated: Oct 9, 2026

Determining the Reactivity and Titre of Serum using a Haemagglutination Assay
Published on: January 29, 2010
Value of reflex testing based on hypogammaglobulinemia as demonstrated in serum protein electrophoresis
Pak Cheung Chan1, Jialun Chen2
1Department of Clinical Pathology, Sunnybrook Health Sciences Centre, Ontario; Department of Laboratory Medicine and Pathobiology, University of Toronto, Ontario, Canada.
Objectives:
Hypo-gammaglobulinemia (hypoGG) in serum protein electrophoresis (SPE) reflects, variably, reduced serum immunoglobulin (Ig) concentrations, which may be caused by hematological neoplasms, among other causes. HypoGG in the absence of a discernible M-spike (MC) has been the basis of reflexive testing e.g., by immunofixation electrophoresis (IFE). However, the utility of this practice has not been fully evaluated. Thus, we aimed to (1) determine the predictive power of hypoGG for reduced Ig levels, (2) compare the IFE positive rates and sensitivity between hypoGG and non-hypoGG patients, and (3) examine the M-protein isotype distributions.
Methods:
We retrospectively analyzed 3974 matched SPE and IFE results at the Sunnybrook Health Sciences Centre from January 2010 to June 2013. SPE and IFE were performed on the Sebia Capillarys™ 2 and Hydrasys™ systems respectively.
Results:
2723/3974 (68.5%) patients were SPE negative, 246/2723 (9%) had hypoGG and 192 (7.1%) were IFE positive. HypoGG predicted 93.1% cases with at least one Ig reduction. Among SPE-negative patients, the IFE positive rate and sensitivity in hypoGG were 12.2% and 15.6% respectively, compared to 6.4% and 77.1% in normo-GG. Proportion of non-IgG isotypes in both groups were comparable but fewer MC were detected in hypoGG.
Conclusions:
Both the 7% false negative rate of SPE and the poor sensitivity (16%) of reflex testing based on hypoGG should be taken into consideration when devising a screening strategy based on SPE.
More Related Videos
06:15Characterization of Thymus-dependent and Thymus-independent Immunoglobulin Isotype Responses in Mice Using Enzyme-linked Immunosorbent Assay
Published on: September 7, 2018
07:10Application of Biochip Microfluidic Technology to Detect Serum Allergen-specific Immunoglobulin E sIgE
Published on: April 21, 2019
Related Concept Videos
Humoral Immune Responses
Reflex Activity
A reflex exam is a diagnostic procedure performed by a healthcare professional to evaluate the functionality of a patient's...