Related Experiment Video
Updated: Apr 15, 2026

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Incorporating multislice imaging into x-ray CT polymer gel dosimetry
H Johnston1, M Hilts2, A Jirasek3
1Department of Physics and Astronomy, University of Victoria, Victoria, British Columbia V8W 2Y2, Canada.
Multislice computed tomography (CT) scanning offers faster and more reliable radiation therapy (RT) dose distribution analysis using CT polymer gel dosimetry (PGD). This advanced technique improves scanning time and tube load characteristics compared to single-slice methods.
Area of Science:
- Medical Physics
- Radiotherapy
- Imaging Technology
Background:
- Accurate dose distribution measurement is crucial in radiation therapy (RT).
- CT polymer gel dosimetry (PGD) is a method for measuring RT dose distributions.
- Evaluating advanced imaging techniques for PGD is essential for improving accuracy and efficiency.
Purpose of the Study:
- To assess multislice computed tomography (CT) scanning for rapid and dependable readout of RT dose distributions using CT PGD.
- To establish a baseline for image noise and uniformity in unirradiated gel dosimeters with multislice CT.
Main Methods:
- Images were acquired using a 16-slice CT scanner and a single-slice machine for comparison.
- A novel slice-by-slice background subtraction technique was developed to correct for CT number variability.
- Image quality, noise, uniformity, and scan time were evaluated for both systems.
Main Results:
- Slice-by-slice background subtraction effectively removed artifacts in multislice CT PGD.
- Multislice CT scanning reduced scan time by a factor of 4 and eliminated variations due to x-ray tube load.
- While image noise was higher in multislice CT, overall image quality was comparable to single-slice CT.
Conclusions:
- Multislice CT imaging is a superior technique for CT PGD compared to single-slice imaging.
- The method offers significant advantages in scan time and tube load characteristics.
- Multislice CT scanning is expected to facilitate routine gel dosimetry for complex dose distributions in RT centers.