Related Experiment Video
Updated: Apr 15, 2026

Protocol and Guidelines for Point-of-Care Lung Ultrasound in Diagnosing Neonatal Pulmonary Diseases Based on International Expert Consensus
Published on: March 6, 2019
Indication-based national diagnostic reference levels for paediatric CT: a new approach with proposed values
H Järvinen1, R Seuri2, M Kortesniemi2
1Radiation and Nuclear Safety Authority (STUK), PO Box 14, 00881 Helsinki, Finland hannu.jarvinen@stuk.fi.
New national diagnostic reference levels (DRLs) for paediatric computed tomography (CT) examinations are proposed. These DRLs, based on patient weight and specific CT indications, are generally lower than international benchmarks.
Area of Science:
- Medical Imaging
- Radiology
- Radiation Protection
Background:
- Establishing diagnostic reference levels (DRLs) is crucial for optimizing radiation dose in paediatric computed tomography (CT).
- Existing DRLs may not adequately address the variability in patient size and specific examination indications in paediatric populations.
- Paediatric CT examinations require tailored dose optimization strategies due to anatomical and physiological differences.
Purpose of the Study:
- To propose indication-based national diagnostic reference levels (DRLs) for common paediatric computed tomography (CT) examinations.
- To develop DRLs that account for patient weight and specific clinical indications.
- To provide a benchmark for radiation dose optimization in paediatric CT.
Main Methods:
- Collected patient dose data (CTDIvol and dose length product) from over 1000 paediatric patients across four university hospitals.
- Analyzed dose data for common CT indications including chest, abdomen, abdomen+pelvis, chest+abdomen, and head CT.
- Developed DRLs as exponential curves based on patient weight for body examinations and age groups for head CT.
Main Results:
- Proposed DRL curves (75% and 50% levels) as a function of patient weight for body CT examinations, applicable across multiple indications.
- Established age-specific DRLs for head CT, differentiating between routine scans and those for ventricular size assessment.
- The proposed DRLs were found to be generally lower than previously published DRLs from other countries.
Conclusions:
- The proposed indication-based DRLs provide a more refined approach to radiation dose management in paediatric CT.
- The weight- and age-based DRL curves facilitate tailored dose optimization across diverse paediatric patient groups and indications.
- These lower proposed DRLs suggest potential for improved radiation safety in paediatric imaging practices.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Pharmacokinetics in Pediatric Patients: Drug Excretion
Drug Dosing: Infants and Children