Related Experiment Video
Updated: Apr 15, 2026

Whole-body PET/MRI of Pediatric Patients: The Details That Matter
Published on: December 19, 2017
Patient grouping for dose surveys and establishment of diagnostic reference levels in paediatric computed tomography
1International Atomic Energy Agency, Vienna, Austria j.vassileva@iaea.org.
Insights
For pediatric dose surveys in resource-limited settings, grouping patients by four age categories (<1, 1-5, 5-10, >10-15 years) is pragmatic. This approach ensures accuracy for establishing diagnostic reference levels (DRLs) when patient weight data is unavailable.
Area of Science:
- Medical Imaging
- Radiological Physics
- Public Health
Background:
- Paediatric patient grouping for dose surveys lacks standardization, causing literature confusion.
- Accurate patient dose surveys are crucial, especially in resource-limited countries.
Purpose of the Study:
- To propose a practical method for paediatric patient grouping in dose surveys.
- To ensure reasonable accuracy for dose surveys and diagnostic reference levels (DRLs) in resource-limited settings.
Main Methods:
- Analysis of paediatric computed tomography (CT) dose data from 82 facilities in 32 countries.
- Involved 6115 patients, with weight data available for 34.5%.
Main Results:
- Suggests using four age groups: <1, >1-5, >5-10, and >10-15 years.
- Recommends collecting data for >30 patients per age group if weight is unknown.
- If sample size is smaller, patient weight must be recorded, with median weight within 5-10% of established DRLs.
Conclusions:
- The proposed four-age-grouping strategy is realistic and pragmatic for dose surveys in less resourced countries.
- Ensures relevant accuracy for establishing DRLs.
- Highlights the importance of considering patient grouping methods when comparing survey results and suggests methods for dose result correction.
Abstract:
There has been confusion in literature on whether paediatric patients should be grouped according to age, weight or other parameters when dealing with dose surveys. The present work aims to suggest a pragmatic approach to achieve reasonable accuracy for performing patient dose surveys in countries with limited resources. The analysis is based on a subset of data collected within the IAEA survey of paediatric computed tomography (CT) doses, involving 82 CT facilities from 32 countries in Asia, Europe, Africa and Latin America. Data for 6115 patients were collected, in 34.5 % of which data for weight were available. The present study suggests that using four age groups, <1, >1-5, >5-10 and >10-15 y, is realistic and pragmatic for dose surveys in less resourced countries and for the establishment of DRLs. To ensure relevant accuracy of results, data for >30 patients in a particular age group should be collected if patient weight is not known. If a smaller sample is used, patient weight should be recorded and the median weight in the sample should be within 5-10 % from the median weight of the sample for which the DRLs were established. Comparison of results from different surveys should always be performed with caution, taking into consideration the way of grouping of paediatric patients. Dose results can be corrected for differences in patient weight/age group.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Drug Dosing: Infants and Children
Imaging Studies III: Computed Tomography
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation I: X-ray and CT
Dosage Regimen Designs: Nomograms and Tabulations