Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
An international survey of imaging practices in radiotherapy
C J Martin1, T Kron2, J Vassileva3
1Dept. of Clinical Physics and Bio-Engineering, University of Glasgow, Gartnavel Royal Hospital, Glasgow G12 0XH, UK; Task Group 116 member, International Commission on Radiological Protection, 280 Slater Street, Ottawa, Ontario K1P 5S9, Canada.
Abstract:
Improvements in delivery of radiation dose to target tissues in radiotherapy have increased the need for better image quality and led to a higher frequency of imaging patients. Imaging for treatment planning extends to function and motion assessment and devices are incorporated into medical linear accelerators (linacs) so that regions of tissue can be imaged at time of treatment delivery to ensure dose distributions are delivered as accurately as possible. A survey of imaging in 97 radiotherapy centres in nine countries on six continents has been undertaken with an on-line questionnaire administered through the International Commission on Radiological Protection mentorship programme to provide a snapshot of imaging practices. Responses show that all centres use CT for planning treatments and many utilise additional information from magnetic resonance imaging and positron emission tomography scans. Most centres have kV cone beam CT attached to at least some linacs and use this for the majority of treatment fractions. The imaging options available declined with the human development index (HDI) of the country, and the frequency of imaging during treatment depended more on country than treatment site with countries having lower HDIs imaging less frequently. The country with the lowest HDI had few kV imaging facilities and relied on MV planar imaging intermittently during treatment. Imaging protocols supplied by vendors are used in most centres and under half adapt exposure conditions to individual patients. Recording of patient doses, a knowledge of which is important in optimisation of imaging protocols, was limited primarily to European countries.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
X-ray Imaging
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...