Related Experiment Video
Updated: Apr 15, 2026

Continuously-stirred Anaerobic Digester to Convert Organic Wastes into Biogas: System Setup and Basic Operation
Published on: July 13, 2012
Anaerobic digestion performance of vinegar residue in continuously stirred tank reactor
Lin Li1, Lu Feng2, Ruihong Zhang3
1Biomass Energy and Environmental Engineering Research Center, College of Chemical Engineering, Beijing University of Chemical Technology, Beijing 100029, China.
Abstract:
Anaerobic digestion (AD) of vinegar residue was investigated in continuously stirred tank reactor (CSTR). The influence of organic loading rate (OLR) and effluent recirculation on AD performance of vinegar residue was tested. Five OLRs, 1.0, 1.5, 2.0, 2.5, and 3.0 g(vs) L(-1) d(-1), were used. The highest volumetric methane productivity of 581.88 mL L(-1) was achieved at OLR of 2.5 g(vs) L(-1) d(-1). Effluent reflux ratio was set as 50%, the results showed that effluent recirculation could effectively neutralize the acidity of vinegar residue, raise the pH of the feedstock, and enhance the buffering capacity of the AD system. Anaerobic digestion of vinegar residue could be a promising way not only for converting this waste into gas energy but also alleviating environmental pollution which might be useful for future industrial application.