Related Experiment Video
Updated: Apr 15, 2026

Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
Flow-Dependent Uptake of ¹²³I-CMICE-013, a Novel SPECT Perfusion Agent, Compared with Standard Tracers
R Glenn Wells1, Lihui Wei2, Julia Petryk3
1Division of Cardiology, University of Ottawa Heart Institute, Ottawa, Ontario, Canada Canadian Molecular Imaging Center of Excellence (CMICE), University of Ottawa Heart Institute, Ottawa, Ontario, Canada; and gwells@ottawaheart.ca.
Unlabelled:
Rotenone derivatives have shown promise in myocardial perfusion imaging (MPI). CMICE-013 is a novel (123)I-labeled rotenone derivative developed for SPECT MPI. The objective of this study was to assess the image quality of CMICE-013 and compare its uptake with tetrofosmin, sestamibi, and (201)Tl in vivo in a porcine model of stress-induced myocardial ischemia.
Methods:
Microspheres were injected simultaneously with the radiotracer injections at rest and stress to measure blood flow. Mimicking a 1-d tetrofosmin protocol, stress imaging used 3 times as much activity and occurred 1 h after the rest injection. SPECT images were obtained at both rest and stress. After imaging, the heart was sectioned into 44-50 pieces. In each heart sample, the tracer uptake was measured in a γ counter. The images were aligned, and the decay-corrected ratio of the signals at rest and stress was used to separate the well-counter signal into rest and stress components. The uptake at rest and stress was compared with microsphere flow measurements.
Results:
The CMICE-013 images showed good contrast between the heart and surrounding organs, with heart-to-liver and heart-to-lung uptake ratios similar to those of the standard tracers. Uptake of CMICE-013 was 1.5% of the injected dose at rest and increased more rapidly with increased blood flow than did the standard SPECT tracers. The percentage injected dose of CMICE-013 taken up by the heart was greater (P < 0.05) than (201)Tl, tetrofosmin, or sestamibi at flows greater than 1.5 mL/min/g.
Conclusion:
CMICE-013 is a promising new SPECT MPI agent.