Related Experiment Video
Updated: Apr 15, 2026

An Experimental and Finite Element Protocol to Investigate the Transport of Neutral and Charged Solutes across Articular Cartilage
Published on: April 23, 2017
Material properties of individual menisci and their attachments obtained through inverse FE-analysis
Maren Freutel1, Fabio Galbusera2, Anita Ignatius1
1Institute of Orthopaedic Research and Biomechanics, Centre of Musculoskeletal Research Ulm, University of Ulm, Ulm, Germany.
Abstract:
Meniscal properties for computational methods have already been proposed. However, it is well known that there is high intra subject variability in the material properties of soft tissues and that disruption of the fiber network alters the biomechanics of the meniscus. Therefore, the objective of this study was to establish a non invasive method to determine the material properties of the individual menisci and their attachments using inverse FE-analyses. In a previous study, the 3D displacements of the meniscus and its attachments under axial joint loads were determined for intact porcine knees. To simulate the experimental response in individual FE-analyses (n=5), an anisotropic, hyperelastic meniscus matrix was embedded in a poroelastic model. During a particle swarm optimization, the difference between the force applied to the meniscus during the experiment and the femoral surface reaction force of the FE model at equilibrium was minimized by varying four material parameters. Afterwards, a prediction error was determined to describe how well the material parameter fit to each of the three displacement directions. Additionally, the stresses occurring in the meniscus were evaluated. The error of the material parameter optimization was on average 6.5±4.4%. The best fitting material parameter combination revealed an error of 1.2%. The highest stresses occurred in the region between the pars intermedia and posterior horn of the meniscus. The individual material properties of the meniscus were successfully obtained with a combination of previously reported, noninvasively measured 3D displacements and inverse FE-analyses. The methodology presented in this study is a promising contribution to the detection of degeneration within the meniscus.
More Related Videos
09:32Subject-specific Musculoskeletal Model for Studying Bone Strain During Dynamic Motion
Published on: April 11, 2018
06:18Intravascular Ultrasound Image-Based Finite Element Modeling Approach for Quantifying In Vivo Mechanical Properties of Human Coronary Artery
Published on: December 6, 2024
Related Concept Videos
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Shear and Bending Moment Diagram: Problem Solving
Draw a Free-Body Diagram: Start by drawing a free-body diagram of the entire beam, including the concentrated loads, distributed load, and reaction...
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...
Bending of Curved Members - Strain Analysis
The important part of bending analysis for such a member...
Method of Joints: Problem Solving II