Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Trilinearity deviation ratio: a new metric for chemometric analysis of comprehensive two-dimensional gas
David K Pinkerton1, Brendon A Parsons1, Todd J Anderson1
1Department of Chemistry, Box 351700, University of Washington, Seattle, WA 98195-1700, USA.
Abstract:
Comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry (GC×GC-TOFMS) is a well-established instrumental platform for complex samples. However, chemometric data analysis is often required to fully extract useful information from the data. We demonstrate that retention time shifting from one modulation to the next, Δ(2)tR, is not sufficient alone to quantitatively describe the trilinearity of a single GC×GC-TOFMS run for the purpose of predicting the performance of the chemometric method parallel factor analysis (PARAFAC). We hypothesize that analyte peak width on second dimension separations, (2)Wb, also impacts trilinearity, along with Δ(2)tR. The term trilinearity deviation ratio, TDR, which is Δ(2)tR normalized by (2)Wb, is introduced as a quantitative metric to assess accuracy for PARAFAC of a GC×GC-TOFMS data cube. We explore how modulation ratio, MR, modulation period, PM, temperature programming rate, Tramp, sampling phase (in-phase and out-of-phase), and signal-to-noise ratio, S/N, all play a role in PARAFAC performance in the context of TDR. Use of a PM in the 1-2 s range provides an optimized peak capacity for the first dimension separation (500-600) for a 30 min run, with an adequate peak capacity for the second dimension separation (12-15), concurrent with an optimized two-dimensional peak capacity (6000-7500), combined with sufficiently low TDR values (0-0.05) to facilitate low quantitative errors with PARAFAC (0-0.5%). In contrast, use of a PM in the 5s or greater range provides a higher peak capacity on the second dimension (30-35), concurrent with a lower peak capacity on the first dimension (100-150) for a 30 min run, and a slightly reduced two-dimensional peak capacity (3000-4500), and furthermore, the data are not sufficiently trilinear for the more retained second dimension peaks in order to directly use PARAFAC with confidence.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
High-Resolution Mass Spectrometry (HRMS)
Tandem Mass Spectrometry
Gas Chromatography: Types of Detectors-II