Related Experiment Video
Updated: Apr 15, 2026

Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Patient doses from PET-CT procedures
S Avramova-Cholakova1, S Ivanova2, E Petrova3
1National Centre of Radiobiology and Radiation Protection, Sofia, Bulgaria s_avramova@mail.bg.
Abstract:
Positron emission tomography (PET) was installed for the first time in Bulgaria in 2009, and nowadays two hybrid PET-computed tomography (CT) systems are in operation. The aim of this work is to estimate patient doses from PET-CT procedures and to explore potential for optimisation. Data were retrospectively collected for 50 patients examined with the system Philips Gemini TF and for 58 patients examined with the system GE Discovery 600. Whole-body examinations with radiopharmaceutical (18)F-2-fluoro-2-deoxy-D-glucose (FDG) were performed on all patients. Patient effective doses from the CT component of the examination were calculated with CT Expo software and compared with doses estimated applying the National Radiological Protection Board (NRPB) conversion coefficients. Effective doses from the PET component were calculated applying the ICRP 80 conversion coefficients. For the first system, average effective doses from CT component were 8.0 and 8.9 mSv, applying CT Expo and NRPB coefficients, respectively, and 4.9 mSv from PET component. For the second system, the corresponding values were 7.8, 8.7 and 5.9 mSv. These results for patient effective doses are relatively lower or comparable to other similar surveys. Reasons for the observed differences are analysed and presented.
More Related Videos
10:48PET and MRI Guided Irradiation of a Glioblastoma Rat Model Using a Micro-irradiator
Published on: December 28, 2017
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET