Related Experiment Video
Updated: Apr 15, 2026

Clinical Imaging of Microwave Mammography
Published on: November 14, 2025
Digital breast tomosynthesis in one or two views as a replacement or adjunct technique to full-field digital
1School of Public Health, Sydney Medical School, University of Sydney, Sydney 2006, NSW, Australia tonymartinsvahn@gmail.com.
Abstract:
Clinical studies using different imaging protocols to perform digital breast tomosynthesis (DBT) were reviewed (2008-14) to assess interpretive accuracy. Descriptive pooled statistics were used to estimate and summarise accuracy measures for each type of imaging protocol in relation to that of two-view full-field digital mammography (FFDM). In studies comparing multiple DBT imaging protocols, a trend of increased performance was often seen when including both the mediolateral oblique and craniocaudal views for DBT alone and even more so for DBT adjunct to FFDM. Overall, the average ΔAUC (%; sd) across studies for stand-alone DBT (relative to FFDM), in one and in two views, were 2.2 (± 3.7) and 5.9 (± 4.6), and when used together with FFDM, 3.9 (± 2.0) and 6.7 (± 0.9). With respect to individual studies, improvements in accuracy using DBT were present for different types of imaging protocols although the magnitude of the impact varied between studies, and some studies did not show significant improvements in comparison with FFDM. The most consistent effect of improvement in breast cancer detection was seen across studies for two-view DBT with FFDM. These summary findings may depend on the sampling constraints present in tomosynthesis imaging and on other factors discussed in this paper. In order to investigate these effects more thoroughly and how they might impact outcomes, comparative or randomized-controlled trials are warranted.
More Related Videos
15:48Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
12:24Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
Published on: July 17, 2012
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography