Related Experiment Video
Updated: Apr 15, 2026

Magnetic Resonance Derived Myocardial Strain Assessment Using Feature Tracking
Published on: February 12, 2011
Myocardial feature tracking reduces observer-dependence in low-dose dobutamine stress cardiovascular magnetic
Andreas Schuster1, Matthias Paul2, Nuno Bettencourt3
1Department of Cardiology and Pulmonology, Georg-August-University and German Center for Cardiovascular Research (DZHK, Partner Site), Göttingen, Germany; King's College London British Heart Foundation (BHF) Centre of Excellence; National Institute of Health Research (NIHR) Biomedical Research Centre at Guy's and St. Thomas' NHS Foundation Trust; Wellcome Trust and Engineering and Physical Sciences Research Council (EPSRC) Medical Engineering Centre; Division of Imaging Sciences and Biomedical Engineering; The Rayne Institute, St. Thomas´ Hospital, London, United Kingdom.
Objectives:
To determine whether quantitative wall motion assessment by CMR myocardial feature tracking (CMR-FT) would reduce the impact of observer experience as compared to visual analysis in patients with ischemic cardiomyopathy (ICM).
Methods:
15 consecutive patients with ICM referred for assessment of hibernating myocardium were studied at 3 Tesla using SSFP cine images at rest and during low dose dobutamine stress (5 and 10 μg/kg/min of dobutamine). Conventional visual, qualitative analysis was performed independently and blinded by an experienced and an inexperienced reader, followed by post-processing of the same images by CMR-FT to quantify subendocardial and subepicardial circumferential (Eccendo and Eccepi) and radial (Err) strain. Receiver operator characteristics (ROC) were assessed for each strain parameter and operator to detect the presence of inotropic reserve as visually defined by the experienced observer.
Results:
141 segments with wall motion abnormalities at rest were eligible for the analysis. Visual scoring of wall motion at rest and during dobutamine was significantly different between the experienced and the inexperienced observer (p<0.001). All strain values (Eccendo, Eccepi and Err) derived during dobutamine stress (5 and 10 μg/kg/min) showed similar diagnostic accuracy for the detection of contractile reserve for both operators with no differences in ROC (p>0.05). Eccendo was the most accurate (AUC of 0.76, 10 μg/kg/min of dobutamine) parameter. Diagnostic accuracy was worse for resting strain with differences between operators for Eccendo and Eccepi (p<0.05) but not Err (p>0.05).
Conclusion:
Whilst visual analysis remains highly dependent on operator experience, quantitative CMR-FT analysis of myocardial wall mechanics during DS-CMR provides diagnostic accuracy for the detection of inotropic reserve regardless of operator experience and hence may improve diagnostic robustness of low-dose DS-CMR in clinical practice.
More Related Videos
11:13Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010