Monitor height ergonomics: A comparison of operating room video display terminals
Gregory I Kelts1, Kevin C McMains, Phillip G Chen
1San Antonio Uniformed Services Health Education Consortium, Department of Otolaryngology, San Antonio, Texas, USA.
Abstract:
A surgeon's eyes should be positioned 1 meter (m) distant and no more than 15° below the top of an operating monitor (0.27 m). We sought to determine which operating room video display terminal can best accommodate ergonomically optimized gaze during surgery. Floor to eye height was measured for surgeons in seated, perched, and standing positions. These ranges were then compared to vertical displacement ranges for monitors measured from floor to top of the screen. Eye height was measured for standing (1.56-1.80 m), perched (1.40-1.65 m), and seated (1.10-1.32 m) positions. The minimum distance (min) between the floor and the top of the monitor and the vertical mobility range (VR) of the monitor were measured throughout a tertiary medical center including towers with boom arms (TcB) (min: 1.58 m, VR: 0.37 m), towers without booms (TsB) (min: 1.82 m, VR: 0.025 m), ceiling mounted booms (CMB) (min: 1.34 m:, VR: 1.04 m), and portable monitors (PM) (min: 1.73 m, VR: 0.04 m). The tangent of 15° declination was used to calculate a correction factor to determine the minimum optimal ergonomic display height. The correction factor was subtracted from the eye height at each position to determine the lowest target height and the highest target floor to eye distance for each position. Analysis of variance with least significant difference post hoc testing identified all minimum distances and vertical ranges to be statistically different (p < 0.001). Monitor vertical displacement varied between styles of carts. CMB video display terminal systems can accommodate standing, perched and the tallest seated surgeons. TcB, TsB and PM systems cannot adequately accommodate all standing, perched or seated surgeons.
More Related Videos
06:30Assessment of Static Graviceptive Perception in the Roll-Plane using the Subjective Visual Vertical Paradigm
Published on: April 28, 2020
07:12Development of a Gaze-Contingent Display Framework Designed for Perceptual and Oculomotor Research with Simulated Central Vision Loss
Published on: April 11, 2025