Related Experiment Video
Updated: Apr 15, 2026

Detection of 3-Nitrotyrosine in Atmospheric Environments via a High-performance Liquid Chromatography-electrochemical Detector System
Published on: January 30, 2019
Electrochemical detection of benzo(a)pyrene in acetonitrile-water binary medium
Chunyan Du1, Yaqi Hu1, Yunchao Li1
1Key Laboratory of Theoretical and Computational Photochemistry, Ministry of Education, College of Chemistry, Beijing Normal University, Beijing 100875, China.
Abstract:
Electrochemical oxidation of adsorbed benzo(a)pyrene (BaP) on the glassy carbon electrode (GCE) was explored in acetonitrile-water. When the GCE was incubated in 100 nM BaP acetonitrile-water (V(water):V(acetonitrile)=1:1) for 10 min at open circuit, and then transferred into blank acetonitrile-water (V(water):V(acetonitrile)=1:1, pH= 0.70) for differential pulse voltammetry measurement, a distinct oxidation peak at 0.98 V (vs. Ag/AgCl) was observed. The peak potential was about 180 mV lower than that in acetonitrile. Importantly, the peak current was more than 22 times greater. The effects of water on BaP preconcentration on the electrode and electrochemical oxidation were revealed, respectively. Based on the results, an electrochemical assay for BaP detection was developed. The GCE was respectively incubated in acetonitrile-water (V(water):V(acetonitrile)=1:1)with BaP concentration ranged from 0 nM to 1000 nM, and then transferred into the corresponding blank acetonitrile-water (pH= 0.70) for DPV measurements. When the BaP concentration was increased, an increased oxidative current at 0.98 V (vs. Ag/AgCl) was observed, and a detection limit of 0.67 nM was achieved. Because all other priority polycyclic aromatic hydrocarbons could not be electrochemically oxidized at 0.98 V, the electrochemical assay showed very high selectivity to BaP. Finally, the developed electrochemical assay was successfully applied to determination of BaP in a series of real world samples, such as drinking water, tap water, lake water and river water.
More Related Videos
13:16A Whole Cell Bioreporter Approach to Assess Transport and Bioavailability of Organic Contaminants in Water Unsaturated Systems
Published on: December 24, 2014
04:39A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
NMR Spectroscopy of Benzene Derivatives
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...