Related Experiment Video
Updated: Apr 15, 2026

Measurement of Tissue Oxygenation Using Near-Infrared Spectroscopy in Patients Undergoing Hemodialysis
Published on: October 2, 2020
Monitoring tissue blood oxygen saturation in the internal jugular venous area using near infrared spectroscopy
1Department of Anesthesiology and Surgical Intensive Care Unit, Xin Hua Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Abstract:
Central venous blood oxygen saturation (ScvO2) is an important monitoring index of fluid resuscitation. However, monitoring of ScvO2 is not continuous and invasive. Near infrared spectroscopy (NIRS) is an optical technology for the noninvasive detection of hemodynamic changes, with advantages of being real-time, continuous, low-cost, and portable. The present study aimed to determine whether a correlation exists between the tissue blood oxygen saturation in the internal jugular venous area (StO2) data obtained with NIRS and the ScvO2 and whether these two quantities are equivalent. Data were collected from 13 patients. We used ultrasound to locate the placement site for the NIRS light source outside the internal jugular vein. Meanwhile, a sample for blood gas analysis was obtained through the central venous catheter. A correlation analysis between the StO2 and ScvO2 of 13 samples was performed (Pearson correlation coefficient), suggesting a high correlation between them (r = 0.906, StO2 =1.0018 ScvO2 +2.8524). Bland-Altman analysis was also performed between the StO2 and ScvO2. Results were as follows: 100% of monitored points fell within the range of the mean ± 1.96 SD of the difference between the StO2 and ScvO2; range of the mean ± 1.96 SD of the difference between the StO2 and ScvO2 was 3 ± 10.2; confidence interval of the difference between the StO2 and ScvO2 was -7.2 to 13.2%. The StO2 monitored with NIRS correlated highly with the ScvO2 measured in the internal jugular vein. Therefore, the StO2 can be used for directing clinical treatment with further research.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
07:27How to Administer Near-Infrared Spectroscopy in Critically ill Neonates, Infants, and Children
Published on: August 19, 2020
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...