Related Experiment Video
Updated: Apr 14, 2026

05:49
Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
1.7K
Detection of Procedural Errors during Root Canal Instrumentation using Cone Beam Computed Tomography.
Orlando Aguirre Guedes1, Marcus Vinícius Corrêa da Costa1, Maura Cristiane Gonçales Orçati Dorilêo1
1Professor, Department of Endodontics, School of Dentistry, University of Cuiabá, Cuiabá, Mato Grosso, Brazil.
Journal of International Oral Health : JIOH
|April 17, 2015
Summary
Cone beam computed tomography (CBCT) identified procedural errors in root canal preparation. The BioRaCe nickel-titanium (NiTi) system demonstrated significantly fewer errors compared to other NiTi instruments.
Area of Science:
- Endodontics
- Dental Materials Science
Background:
- Procedural errors during root canal preparation can compromise treatment outcomes.
- Nickel-titanium (NiTi) instruments are widely used for their flexibility and efficiency.
- Accurate detection of procedural errors is crucial for evaluating instrument performance.
Purpose of the Study:
- To investigate procedural errors in root canal preparation using different NiTi systems.
- To compare the incidence of errors among various NiTi instruments.
- To assess the efficacy of cone beam computed tomography (CBCT) in detecting these errors.
Main Methods:
- 100 human mandibular molars were prepared using five different NiTi systems (BioRaCe, K3, ProTaper, Mtwo, Hero Shaper).
- Cone beam computed tomography (CBCT) imaging was employed to detect procedural errors.
- Evaluated errors included fractured instruments, perforations, and canal transportation.
Main Results:
- A total of 43 procedural errors (14.33%) were detected across 300 root canals.
- Perforations were the most frequent error (58.14%), predominantly in mesiobuccal canals.
- A significant difference in procedural errors was observed between NiTi systems (P < 0.05).
- The BioRaCe system resulted in significantly fewer procedural errors.
Conclusions:
- CBCT is an effective imaging method for detecting procedural errors during root canal preparation.
- The BioRaCe NiTi system demonstrated a lower frequency of procedural errors compared to other tested systems.
- These findings suggest that instrument selection can influence the occurrence of procedural errors in endodontic treatment.
More Related Videos
Related Concept Videos
Computed Tomography
9.7K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
9.7K
Imaging Studies III: Computed Tomography
790
DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
790

