Dual-Energy CT for Patients Suspected of Having Liver Iron Overload: Can Virtual Iron Content Imaging Accurately
Xian Fu Luo1, Xue Qian Xie1, Shu Cheng1
1From the Departments of Radiology (X.F.L., X.Q.X., Y.Y., H.Z., W.M.C., F.H.Y.) and Hematology (S.C.), Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, No. 197, Ruijin 2nd Rd, Shanghai 200025, China; Siemens Shanghai Medical Equipment, Shanghai, China (Y.J.); and Siemens AG, Healthcare Sector, Forchheim, Germany (B.S.).
Purpose:
To prospectively assess the feasibility of using virtual iron content (VIC) imaging at dual-energy computed tomography (CT) to evaluate the liver iron content (LIC) in patients suspected of having liver iron overload and to compare the LIC grading performance of VIC imaging and magnetic resonance (MR) imaging.
Materials And Methods:
This study was approved by the institutional review board, and informed consent was obtained from all patients. Fifty-six patients suspected of having liver iron overload (serum ferritin concentrations >500 μg/L) underwent unenhanced dual-energy CT and MR imaging of the liver. MR imaging-measured LICs were obtained in 34 of the 56 patients. VIC images were generated with dual-energy analysis. R2* and MR-measured LIC were obtained with gradient-echo and spin-echo sequences, respectively. Correlations between CT and MR measurements were analyzed. The diagnostic performance of VIC and R2* in the differentiation of different LIC thresholds were evaluated with receiver operating characteristic (ROC) analysis.
Results:
Hepatic VIC showed significant correlation with R2* and MR-measured LIC (r = 0.885 and 0.871, respectively; P < .0001). To differentiate among different LIC thresholds of 1.8, 3.2, 7.0, and 15.0 mg of iron per gram of dry tissue, the corresponding optimal cutoff values for VIC were 2.50, 5.13, 8.93, and 17.97 HU, respectively. At a LIC threshold of 7.0 mg of iron per gram of dry tissue or higher, 100% sensitivity (15 of 15 patients) and 100% specificity (19 of 19 patients) were obtained for VIC. There was no significant difference between VIC and R2* (area under the ROC curve, 0.964 vs 0.993, respectively; P = .299) in grading LIC levels at a LIC threshold of 3.2 mg of iron per gram of dry tissue or higher. Conclusion Hepatic VIC is a potential index for accurately evaluating and grading clinically significant liver iron accumulation, with a diagnostic performance similar to that of MR imaging.
More Related Videos
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
06:52Positron Emission Tomography Using 64-Copper as a Tracer for the Study of Copper-Related Disorders
Published on: April 28, 2023
Related Concept Videos
Radiological Investigation I: X-ray and CT
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...