Impact on Patient Management and Outcome of Switching between 2 Contemporary Sensitive Cardiac Troponin Assays
Craig B Wilen1, Jeffrey J Szymanski1, Steven Hung2
1Department of Pathology and Immunology.
Background:
Myocardial infarction is characterized by an increase of cardiac troponin I (cTnI) above the 99th percentile of a reference population. Our hospital switched from 1 contemporary cTnI assay to another and observed a doubling of cTnI results above the assays' respective 99th percentile cutoffs. We investigated the potential impact on inpatient management and outcomes.
Methods:
We performed a retrospective cohort study of 45 498 individuals with ≥1 cTnI result between January 2013 and June 2014. The Dimension cTnI assay was used in 2013; the Abbott Architect cTnI assay was used in 2014.
Results:
Before switching cTnI assays, 19.2% (4742/30 872) of patients had at least 1 of the first 3 cTnIs above the 99th percentile (0.07 μg/L). After switching to the Architect cTnI assay, 31.4% (4034/14 626) of patients had at least 1 cTnI above the 99th percentile (0.03 μg/L). This increase was due to the difference in the assays' 99th percentile cutoffs. Having an increased cTnI reported on the Architect assay that would not have been reported as such on the Dimension assay (0.03-0.06 μg/L) correlated with increased inpatient mortality, length of stay, non-ST elevation myocardial infarction diagnosis, therapeutic heparin use, and percutaneous coronary intervention, relative to individuals with cTnI <0.03 μg/L.
Conclusions:
The changes observed in patient outcomes and management were likely due to the increased sensitivity and lower 99th percentile cutoff of the Architect assay. It is important to recognize the potential impact that differences in sensitivity and assay configuration may have on patient management.
More Related Videos
10:12A Sensitive and Specific Quantitation Method for Determination of Serum Cardiac Myosin Binding Protein-C by Electrochemiluminescence Immunoassay
Published on: August 8, 2013
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
Related Concept Videos
Acute Coronary Syndrome III: Diagnostic Studies
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Acute Coronary Syndrome I: Introduction
Acute Coronary Syndrome II: Pathophysiology and Clinical Manifestations
Therapeutic Drug Monitoring: Affecting Factors
Cardiac Catheterization IV: Nursing Management