Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Computed Tomography01:10

Computed Tomography

9.7K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
9.7K
Imaging Studies II: Positron Emission Tomography and Scintigraphy01:25

Imaging Studies II: Positron Emission Tomography and Scintigraphy

785
Positron Emission Tomography (PET) is a medical imaging technique that provides crucial insights into the body's physiological functions at a molecular level. It is an indispensable resource for diagnosing, staging, and monitoring various illnesses, notably cancer, neurological disorders, and cardiovascular conditions.
Fundamental Principles of PET
785
Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

790
DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
790
Imaging Studies I: CT and MRI01:14

Imaging Studies I: CT and MRI

1.3K
Introduction: MRI and CT scans are crucial advancements in medical imaging techniques, playing a vital role in diagnosing conditions related to the gastrointestinal (GI) system. Each scan serves distinct purposes, targets specific areas, and requires unique nursing duties.
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
1.3K
Imaging Studies for Cardiovascular System V: CT01:28

Imaging Studies for Cardiovascular System V: CT

615
Cardiac computed tomography (CT) scanning is an advanced cardiac imaging technique that utilizes CT technology, with or without intravenous (IV) contrast, to produce accurate cross-sectional virtual slices of specific areas of the heart, coronary circulation, and major blood vessels such as the aorta, pulmonary veins, and arteries. The computer processes these slices to generate three-dimensional images. Multidetector CT (MDCT) is a rapid form of CT scanning that captures multiple slices...
615

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Implementation of generic and individual justification: Findings from a survey under the IAEA technical cooperation programme in Europe and Central Asia.

European journal of radiology·2025
Same author

Dysprosium-Doped Glass-Ceramics From the System Na<sub>2</sub>O-Al<sub>2</sub>O<sub>3</sub>-SiO<sub>2</sub>-B<sub>2</sub>O<sub>3</sub>-Dy<sub>2</sub>O<sub>3</sub>.

Luminescence : the journal of biological and chemical luminescence·2024
Same author

2021 NATIONAL DIAGNOSTIC REFERENCE LEVELS FOR PAEDIATRIC COMPUTED TOMOGRAPHY IN EGYPT.

Radiation protection dosimetry·2022
Same author

IAEA support to the radiation protection of patients in the time of the COVID-19 global pandemic.

Health and technology·2022
Same author

An international survey of imaging practices in radiotherapy.

Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)·2021
Same author

Large differences in education and training of radiographers in Europe and Central Asia: Results from an IAEA coordinated study.

Radiography (London, England : 1995)·2021

Related Experiment Video

Updated: Apr 14, 2026

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
09:49

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods

Published on: April 24, 2020

10.6K

Dosimetry methods for multi-detector computed tomography.

M Gancheva1, I Dyakov2, J Vassileva2

  • 1National Centre of Radiobiology and Radiation Protection, Sofia, Bulgaria mvgancheva@gmail.com.

Radiation Protection Dosimetry
|April 19, 2015
PubMed
Summary
This summary is machine-generated.

This study compared four dosimetry methods for wide-beam multi-detector computed tomography (MDCT). Results show significant variations in computed tomography dose index (CTDI) measurements, highlighting the need for standardized dosimetry protocols in MDCT imaging.

More Related Videos

Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
08:36

Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner

Published on: June 7, 2024

835
Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
12:24

Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers

Published on: July 17, 2012

13.0K

Related Experiment Videos

Last Updated: Apr 14, 2026

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
09:49

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods

Published on: April 24, 2020

10.6K
Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
08:36

Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner

Published on: June 7, 2024

835
Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
12:24

Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers

Published on: July 17, 2012

13.0K

Area of Science:

  • Medical Physics
  • Radiological Sciences
  • Imaging Technology

Background:

  • Accurate radiation dose assessment is crucial for patient safety in multi-detector computed tomography (MDCT).
  • Existing dosimetry methods may yield variable results, particularly with wide beams, necessitating comparative studies.
  • Standardization of dose metrics like computed tomography dose index (CTDI) is essential for reliable comparisons across different scanners and protocols.

Purpose of the Study:

  • To compare four distinct dosimetry methods for wide-beam MDCT.
  • To evaluate computed tomography dose index free-in-air (CTDI free-in-air) and CTDI measured in phantom (CTDI phantom) across different methods.
  • To assess the accuracy and consistency of dosimetry techniques on various MDCT scanners.

Main Methods:

  • Four dosimetry methods were applied to Toshiba Aquilion One, Philips Ingenuity, and Toshiba Aquilion 64 MDCT scanners.
  • Methods included standard dosimetry, International Electrotechnical Commission (IEC) recommended free-in-air measurements, a dual-chamber phantom approach, and thermoluminescent detector (TLD) based real-dose profiling.
  • Measurements involved varying integration lengths (200 mm, 300 mm) and beam widths (160 mm, 40 mm, 32 mm).

Main Results:

  • CTDI free-in-air measurements with a 300 mm integration length and 160 mm beam width were 194% higher than standard methods.
  • For a 200 mm integration length, differences ranged from 14-18% for narrower beams (32-40 mm).
  • IEC method phantom measurements showed differences of 18-41% compared to CTDI vol, and dual-chamber measurements differed by 20% from IEC calculations.

Conclusions:

  • Significant discrepancies exist between various dosimetry methods for wide-beam MDCT.
  • The IEC method and dual-chamber approach show notable deviations from standard CTDI measurements, especially with wider beams.
  • Further research and standardization are needed to ensure accurate dose reporting in advanced MDCT imaging.