Imaging Biological Samples with Optical Microscopy01:18

Imaging Biological Samples with Optical Microscopy

12.3K
Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
12.3K
Overview of Microscopy Techniques01:22

Overview of Microscopy Techniques

17.8K
The early pioneers of microscopy opened a window into the invisible world of microorganisms. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes that leveraged nonvisible light, such as fluorescence microscopy that uses an ultraviolet light source and electron microscopy that uses short-wavelength electron beams. These advances significantly improved magnification, image resolution, and contrast. By comparison, the...
17.8K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Endophthalmitis rates following intravitreal injection of aflibercept using a prefilled syringe - a multicenter study.

Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie·2026
Same author

First-in-Human Clinical Evaluation of a Novel Nonsurgical Suprachoroidal Delivery Approach for Triamcinolone in Diabetic Macular Edema.

Ophthalmology science·2026
Same author

Artificial intelligence in retinal care: transforming the doctor-patient partnership.

International journal of retina and vitreous·2026
Same author

Near-Real Surgical Specimens (NRSS): A Novel Platform for Standardized Assessment of Suprachoroidal Drug Delivery.

Translational vision science & technology·2025
Same author

GONet: A Generalizable Deep Learning Model for Glaucoma Detection.

IEEE transactions on bio-medical engineering·2025
Same author

Wait times in pediatric ophthalmology clinics: Insights from a tertiary university hospital.

European journal of ophthalmology·2025

Related Experiment Video

Updated: Apr 14, 2026

Step By Step: Microsurgical training method combining two nonliving animal models
05:25

Step By Step: Microsurgical training method combining two nonliving animal models

Published on: May 9, 2015

16.2K

Focusing the surgical microscope.

Sergiu D Socea1, Yoreh Barak1, Eytan Z Blumenthal1

  • 1Department of Ophthalmology, Rambam Health Care Campus, Haifa, Israel.

Survey of Ophthalmology
|April 21, 2015
PubMed
Summary

Achieve optimal operating microscope focus with the novel sloping paper calibration method. This technique addresses surgeon visualization needs, including asthenopia and focusing issues, for clearer surgical views.

Keywords:
focusfocusingmicroscopesurgical microscope

More Related Videos

High-Speed Ultraviolet Photoacoustic Microscopy for Histological Imaging with Virtual-Staining assisted by Deep Learning
09:31

High-Speed Ultraviolet Photoacoustic Microscopy for Histological Imaging with Virtual-Staining assisted by Deep Learning

Published on: April 28, 2022

3.6K
Learning Modern Laryngeal Surgery in a Dissection Laboratory
07:30

Learning Modern Laryngeal Surgery in a Dissection Laboratory

Published on: March 18, 2020

8.9K

Related Experiment Videos

Last Updated: Apr 14, 2026

Step By Step: Microsurgical training method combining two nonliving animal models
05:25

Step By Step: Microsurgical training method combining two nonliving animal models

Published on: May 9, 2015

16.2K
High-Speed Ultraviolet Photoacoustic Microscopy for Histological Imaging with Virtual-Staining assisted by Deep Learning
09:31

High-Speed Ultraviolet Photoacoustic Microscopy for Histological Imaging with Virtual-Staining assisted by Deep Learning

Published on: April 28, 2022

3.6K
Learning Modern Laryngeal Surgery in a Dissection Laboratory
07:30

Learning Modern Laryngeal Surgery in a Dissection Laboratory

Published on: March 18, 2020

8.9K

Area of Science:

  • Ophthalmology
  • Surgical Technology
  • Microscopy

Background:

  • Clear visualization is paramount for surgeons during procedures.
  • Operating microscopes present challenges like asthenopia and focusing issues due to zoom, accommodation, and presbyopia.
  • Existing methods may not fully address all visualization needs secondary to clarity.

Purpose of the Study:

  • To introduce a practical method for achieving optimal focus in operating microscopes.
  • To address secondary visualization needs, including those related to the assistant, video/monitor sharpness, field of view, and user-reported eye strain (asthenopia).

Main Methods:

  • Development and application of the sloping paper calibration method.
  • Focusing on practical solutions for zoom, accommodation, and presbyopia-related issues.
  • Ensuring clarity for the surgeon and other operating room personnel.

Main Results:

  • The sloping paper calibration method provides a practical approach to optimal microscope focus.
  • Addresses key factors affecting surgical visualization, including asthenopia and focusing difficulties.
  • Enhances the overall clarity and effectiveness of the operating microscope.

Conclusions:

  • The sloping paper calibration method offers a valuable tool for optimizing operating microscope performance.
  • Improved focus and visualization can lead to better surgical outcomes.
  • This technique helps mitigate common challenges faced by surgeons using microscopes.