Related Experiment Video
Updated: Apr 14, 2026

Continuous Telemetric In Utero Tracheal Pressure Measurements in Fetal Lambs
Published on: December 22, 2023
Experimental Evaluation of Tracheo-Amniotic Shunting for Induced Congenital High Airway Obstruction in a Sheep Model
Philip DeKoninck1, Masayuki Endo, Jan A Deprest
1Division of Woman and Child, Clinical Department of Obstetrics and Gynecology, Fetal Medicine Unit, University Hospitals Leuven, Leuven, Belgium.
Objective:
To evaluate the feasibility of tracheo-amniotic shunting in a sheep model for congenital high airway obstruction syndrome.
Material And Methods:
High airway obstruction was induced around day 95 (term = 145 days) in 10 lamb fetuses by tracheal clipping. Five days later, ultrasound-guided tracheoamniotic shunting was done using either the Harrison double-pigtail bladder stent (HS) or a double-basket device (BS). Caesarean section (CS) was done around day 110. At each time point, the cardiothoracic index (CTI) was measured. Lung-to-body weight ratio (LBWR) was calculated at fetal necropsy. The primary endpoint was successful shunting defined as anatomically correct placement and functional airway decompression; the secondary endpoint was survival until CS.
Results:
Two sheep aborted 3 fetuses after tracheal occlusion. Overall, the median CTI at CS was significantly smaller compared to baseline [0.52 (interquartile range, IQR: 0.52-0.54) vs. 0.58 (IQR: 0.54-0.63); p = 0.01]. In the HS group (n = 4), none of the shunts were correctly positioned. In the BS group (n = 3), there was 1 correct shunt placement; however, this fetus was stillborn. Median LBWR suggested pulmonary overgrowth [0.10 (IQR: 0.08-0.11)].
Conclusion:
In our hands, using this model with a long and mobile neck and relative oligohydramnios, tracheoamniotic shunting for airway obstruction has a high failure rate. If further pursued, alternative techniques or different models should be considered.